45
The list includes the parameters accessibile to the user, according to the unit configuration some parameters are visible and some not.
User parameters
7 - CONTROL
Num.
Description
Extended description
4
CompExt
Enabling compensation on outdoor temperature
0=No
1=Cool
2=Heat
3=Always
10
MantCoolEn
Enable Summer maintenance
11
MantHeatEn
Enable Winter maintenance
21
RemMode
Configure remote inlets
0=Heat/Cool from digital inlet or H/Sanitary only or C/Sanitary only from ID,
1=H/C from keyboard (digital inlet has no effect)
51
SetCool
System water Summer Set Point
52
SetHeat
System water Winter Set Point
53
SecondSetC
System water Secondary Summer SetPoint
54
SecondSetH
System water secondary Winter SetPoint
112
CExtMaxC
Outdoor Summer temperature at which maximum correction of system water setpoint takes place
113
CExtMinC
Outdoor summer temperature at which minimum correction of system water setpoint takes place
114
CExtMaxH
Outdoor Winter temperature at which maximum correction of system water setpoint takes place
115
CExtMinH
Outdoor Winter temperature at which minimum correction of setpoint takes place
116
MaxCExtC
Maximum correction value of system water setpoint in Summer
117
MaxCExtH
Maximum correction value of system water setpoint in Winter
177
LimitePW
Limit of absorbed power
203
LimitePWID
Limit of power input enabled by digital input
247
SetMantCool
Summer Maintenance Set Point
248
SetMantHeat
Winter Maintenance Set Point
429
SetAccumulo
Set Point sanitary hot water of the indoor accumulation.
431
BandaMant
Maximum variation allowed inside accumulation
435
EnAntilegio
Enable anti-legionella
439
EnRicircolo
0=Not managed,
1=Enabled,
2=Only enabled in Heat,
3=Only enabled in Cool
628
IstTAmb
Ambient temperature hysteresis
Содержание PAC BT Series
Страница 1: ...Installation and operating manual PAC BT 5 kW to 17 kW M0GC6UN16 02 Nov 2016 English version...
Страница 2: ......
Страница 4: ......
Страница 87: ...Airwell Residential AWAU PAC BT UE 5KW H11 AWHK PAC BT UI 5 9KW H11 42 64 3 4 5 XL kW kW kW...
Страница 91: ...Airwell Residential 42 64 4 5 7 XL kW kW kW AWAU PAC BT UE 7KW H11 AWHK PAC BT UI 5 9KW H11...
Страница 95: ...Airwell Residential 42 64 5 6 8 XL kW kW kW AWAU PAC BT UE 9KW H11 AWHK PAC BT UI 5 9KW H11...
Страница 99: ...Airwell Residential 42 68 8 8 10 XL kW kW kW AWAU PAC BT UE 12KW H13 AWHK PAC BT UI 12 17KW H11...
Страница 103: ...Airwell Residential 42 69 9 10 12 XL kW kW kW AWAU PAC BT UE 14KW H13 AWHK PAC BT UI 12 17KW H11...
Страница 107: ...Airwell Residential 42 70 11 11 14 XL kW kW kW AWAU PAC BT UE 17KW H13 AWHK PAC BT UI 12 17KW H11...
Страница 111: ......