5.7 INDOOR UNIT CONNECTION
The holes for passing the electric lines are on the upper part
of the unit.
Remove the protection cover of the hole selected.
Insert the connection cable.
Pass the cable betwe and insert it behind the electrical
panel. (see figure)
Connect the cable to the main isolator switch.
Isolator switch
Connect the line to the main isolator switch inside the
electrical panel.
The minimum section is calculated using a cable type FG7(0)
R 0,6/1 KV .
It is used a different type of cable, the section must be
recalculated by the designer of the electrical system.
Make a hole in the fair lead and insert the cable.
Carry out the connection in accordance with the
electric connection layout .
5 - ELECTRICAL CONNECTIONS
5.8 OUTDOOR UNIT CONNECTIONS
1
Power connections inlet
1
Power connections inlet
2
Outdoor unit connections outlet
Terminal block of the customer connections
Max.24v AC 5A / AC1
ALM (alarm signal)
Used for connecting a visual unit blocked signal device
value description
0 =
input disabled
1 =
Remote ON-OFF input
2 =
Remote mode change input (hot/cold)
3 =
remote system call input
4 =
second remote system set point
Digital input configuration (password protected)
Configuration parameters
parameter
39 ConfigF-DI1
parameter
40 ConfigF-DI2
Different configuration combinations are available using
inputs DI1 and DI2.
HP
*
↳
settings
↳
parame-
ters
↳
configuration
D
I2
=
D
igit
al
inp
ut
1
2V
D
I1
=
D
igit
al
inp
ut
1
2V
XC-F
Remote ON/OFF
Enables the unit to be turned on remotely ( e.g. by a
thermostat or timer)
Remote mode change (hot/cold)
Enables the mode to be changed from heating to cooling by a
remote control unit.
The unit parameters are overwritten by RCW15 keyboard. Make the customization by using RCW15
*
1
2
ALM
Содержание PAC BT Series
Страница 1: ...Installation and operating manual PAC BT 5 kW to 17 kW M0GC6UN16 02 Nov 2016 English version...
Страница 2: ......
Страница 4: ......
Страница 87: ...Airwell Residential AWAU PAC BT UE 5KW H11 AWHK PAC BT UI 5 9KW H11 42 64 3 4 5 XL kW kW kW...
Страница 91: ...Airwell Residential 42 64 4 5 7 XL kW kW kW AWAU PAC BT UE 7KW H11 AWHK PAC BT UI 5 9KW H11...
Страница 95: ...Airwell Residential 42 64 5 6 8 XL kW kW kW AWAU PAC BT UE 9KW H11 AWHK PAC BT UI 5 9KW H11...
Страница 99: ...Airwell Residential 42 68 8 8 10 XL kW kW kW AWAU PAC BT UE 12KW H13 AWHK PAC BT UI 12 17KW H11...
Страница 103: ...Airwell Residential 42 69 9 10 12 XL kW kW kW AWAU PAC BT UE 14KW H13 AWHK PAC BT UI 12 17KW H11...
Страница 107: ...Airwell Residential 42 70 11 11 14 XL kW kW kW AWAU PAC BT UE 17KW H13 AWHK PAC BT UI 12 17KW H11...
Страница 111: ......