Indoor unit cassette type
10)
11) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect,
water may enter the room and damage the furniture.
12) For appliances with supplementary heaters, the minimum clearance from the appliance to
combustible is 50cm other wise, it will cause fire.
Selection of the installation location.
Select an installation location which is rigid and strong enough to support or hold the unit, also
for easy maintenance and repair.
1)
Power supply connection to the room air conditioner.
Connect the power supply cord of the room air conditioner to the mains using one of the
following method.
Power supply point shall be the place where there is ease for access for the power
disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is
prohibited.
2)
Do not release refrigerant.
Do not release refrigerant during piping work for installation, reinstallation and during repairing
a refrigeration parts. Take care of the liquid refrigerant. it may cause frostbite.
3)
4)
Installation work. It may need two people to carry out the installation work.
Do not install this appliance in a laundry room or other location where water may drip from the
ceiling, etc.
5)
The temperature of refrigerant circuit will be high, please keep the interconnection cable away
from the copper tube.
6)
A
TTENTION
3
Do not install the unit: in such places above, there is a risk of unit catching fire.
a) at places where leakage of flammable gas may occur, or oil or vapor or other
flammable substances are in the air
b) above cookers, specially in kitchens
c) close to heating devices where units are exposed to high temperatures.
Important information for the used refrigerant
This product has the fluorinated gas which is listed in Kyoto protocol.
It is forbidden to release to air.
Refrigerant type: R410a Volume of GWP: 2088; tonnes CO2 equivalent
GWP=Global Warming Potential
Attention:
1
)
The fluorinated greenhouse gases are contained in non-hermetically sealed equipment.
2) Installs, services, maintains, repairs, checks for leaks or decommissions equipment and product
recycling should be carried out by natural persons that hold relevant certificates.
3) For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO 2
equivalent or more, but of less than 50 tonnes of CO 2 equivalent: the leakage check should be
performed at least every 12 months; or where a leakage detection system is installed, at least every
24 months.
Содержание KCD
Страница 2: ...10 REFRIGERANT TUBING 18 11 PANEL INSTALLING 20 22 FINAL TASKS 12 1 Indoor unit cassette type 14 16 ...
Страница 14: ...Indoor unit cassette type 13 80mm 80mm Ø75mm MODLE 24 48 Model 24 48 INVERTER 24 48 A 160mm B 95mm NOTE Fig 11 ...
Страница 24: ......
Страница 25: ...DEUTSCH Deutsch Montageanleitung CCD KCD DCC ...
Страница 48: ......
Страница 49: ...FRANCAIS Manuel d installation CLIMATISEUR CASSETTE Type de d unité intérieure cassette CCD KCD DCC ...
Страница 72: ......
Страница 73: ...ESPAÑOL ACONDICIONADOR DE AIRE TIPO CASSETTE Manual de Instalación Unidad Interior Tipo Cassette CCD KCD DCC ...
Страница 96: ......
Страница 120: ......
Страница 121: ...РУССКИЙ Руководство по установке БЛОК ДЛЯ КОНДИЦИОНИРОВАНИЯ ВОЗДУХА Блок внутреннего типа CCD KCD DCC РУССКИЙ ...
Страница 144: ......