CONTROL SYSTEM
11-31
SM TELECOM 1-A.0 GB
11.14
SPT Adjustment in Sleep Mode
x
In COOL, AUTO COOL or DRY modes, the SPT adjustment is positive
(from 0 to +3
o
C).
x
In HEAT or AUTO HEAT modes, the SPT adjustment is negative
(from 0 to -3
o
C).
x
In other modes, there is no SPT adjustment.
x
The SPT adjustment is cancelled when the Sleep mode is cancelled.
SPT
Time [Hr]
4
8
5
3
2
6
Start
Sleep
7
RT
SPT-1
SPT-2
SPT-3
SPT+2
SPT+1
SPT+3
1
7 Hours Sleep operation
for Normal Sleep Mode
Unit is turned to SB
after Sleep
Cool, Dry modes
Heat mode
NOTE
If OFF-timer is active, the unit may go to SB before or after 7 hours of
sleep operation.
CONTENTS
Содержание GC 12 LT
Страница 13: ...OUTLINE DIMENSIONS 4 3 SM TELECOM 1 A 0 GB 4 5 Outdoor Unit GC 30T LT CONTENTS...
Страница 22: ...WIRING DIAGRAMS 7 2 SM TELECOM 1 A 0 GB 7 3 Outdoor Unit GC 12 LT GC 18 LT 7 4 Outdoor Unit GC 30T LT CONTENTS...
Страница 28: ...CONTROL SYSTEM 11 3 SM TELECOM 1 A 0 GB 11 1 4 Main PCB Controller CONTENTS...
Страница 68: ...EXPLODED VIEWS SPARE PARTS LISTS 13 4 SM TELECOM 1 A 0 GB 13 4 Indoor Unit SX 30 TELECOM CONTENTS...
Страница 70: ...EXPLODED VIEWS SPARE PARTS LISTS 13 6 SM TELECOM 1 A 0 GB 13 6 Outdoor Unit GC 12 LT CONTENTS...
Страница 72: ...EXPLODED VIEWS SPARE PARTS LISTS 13 8 SM TELECOM 1 A 0 GB 13 8 Outdoor Unit GC 18 LT CONTENTS...
Страница 78: ...OPTIONAL ACCESSORIES 14 3 SM TELECOM 1 A 0 GB 14 3 RCW RCW2 Wiring Connections as Shown on Kit CONTENTS...
Страница 87: ...APPENDIX A 15 1 SM TELECOM 1 A 0 GB APPENDIX A INSTALLATION AND OPERATION MANUAL CONTENTS...