4

Safety Precautions

Have the unit professionally installed.

Improper installation by an unqualified person may result

in water leak, electric shock, or fire.

Be sure to carefully follow each step in this handbook when

installing the unit.

Improper installation may result in water leak, electric shock,

smoke or fire.

Have all electrical work performed by a licensed electrician

according to the local regulations and the instructions given

in this manual. Secure a circuit designated exclusively to

the unit.

Improper installation or a lack of circuit capacity may cause

the unit to malfunction or present a risk of electric shock,

smoke,and fire.

Place the unit on a stable, level surface that withstands the

weight of the unit to prevent the unit from tipping over or

falling causing injury as a result.

Only use specified cables for wiring. Securely connect each

cable, and make sure that the cables are not straining the

terminals.

Cables not connected securely and properly may generate

heat and cause fire.

Take necessary safety measures against typhoons and

earthquakes to prevent the unit from falling over.

Do not make any changes or modifications to the unit. In

case of problems, consult the dealer.

If repairs are not made properly, the unit may leak water

and present a risk of electric shock, or it may produce smoke

or cause fire.

Securely attach the terminal cover(panel) on the unit.

If installed improperly, dust and/or water may enter the unit

and present a risk of electric shock, smoke or fire.

Only use refrigerant R410A as indicated on the unit when

installing or relocating the unit.

The use of any other refrigerant or an introduction of air into

the unit circuit may cause the unit to run an abnormal cycle

and abnormal cycle and cause the unit to burst.

In the event of a refrigerant gas leak, provide adequate

ventilation to the room.

If leaked refrigerant gas is exposed to a heat source, noxious

gases may form.

Do not touch the fins on the heat exchanger with bare hands,

for they are sharp and dangerous.

Do not try to defeat the safety features of the devices, and

do not change the settings.

Defeating the safety features on the unit such as the pressure

switch and temperature switch or using parts other than the

dealer or specialist may result in fire or explosion.

When installing the unit in a small room, safeguard against

hypoxia that results from leaked refrigerant reaching the

threshold level.

Consult the dealer for necessary measures to take.
When relocating the air conditioner, consult the dealer or

a specialist.

Improper installation may result in water leak, electric shock,

or fire.
After completing the service work, check for a refrigerant

gas leak.

If leaked gas refrigerant is exposed to a heat source such

as fan heater,stove,and electric grill, noxious gases may

form.
Only use specified parts.

Have the unit professionally installed. Improper installation

may cause water leak, electric shock,smoke, or fire.

With All-Fresh type air conditioners, outdoor air may be

directly blown into the room upon thermo off. Take this into

consideration when installing the unit.

Direct exposure to outdoor air may present a health hazard,

and it may also cause food items to deteriorate.

Children should be supervised to ensure that they do not

play with the appliance.

WARNING

WARNING

This appliance is not intended for use by persons (including

children) with reducedphysical, sensory or mental capabilities,

or lack of experience and knowledge, unless they have been

given supervision or instruction concerning use of the

appliance by a person responsible for their safety.

Содержание AWAU-YUDA060-H13

Страница 1: ...OUTDOOR UNIT INSTALLATION MANUAL EN Please read this manual carefully before using this air conditioner Please keep this manual safely for future use R410A AWAU YUDA060 H13...

Страница 2: ......

Страница 3: ......

Страница 4: ...be checked for any damages If the damaged base is not repaired the unit may fall down and cause accidents When need maintenance and repairment call dealer to handle it Incorrect maintenance and repai...

Страница 5: ...to run an abnormal cycle and abnormal cycle and cause the unit to burst In the event of a refrigerant gas leak provide adequate ventilation to the room If leaked refrigerant gas is exposed to a heat...

Страница 6: ...at flares and flange connections Use liquid refrigerant to charge the system Charge the unit with gas refrigerant will cause the refrigerant in the cylinder to change its composition and will lead to...

Страница 7: ...ling draining pipes follow the instructions in the manual and make sure that they properly drain water so as to avoid dew condensation If not installed properly they may cause water leaks and damage t...

Страница 8: ...Refrigerant charging Vacuum Gauze Checking vacuum degree Tools Materials Use Notes Charging Cylinder Refrigerant Charging Must not be used with R410 type units CAUTION Items to Be Checked 1 Verify the...

Страница 9: ...ess If a clutch type flare tool is used to machine flares on units that use R410A make the protruding part of the pipe between 1 0 and 1 5mm Copper pipe gauge for adjusting the length of pipe protrusi...

Страница 10: ...il from flowing back into the refrigerant circuit when the vacuum pump power is turned off power failure It is also possible to attach a check valve to the actual vacuum pump afterwards Standard degre...

Страница 11: ...10 Name of Parts Air inlet Air outlet Compressor Inside of unit YUDA060 YUDA060 will be used as brief model name in this manual AWAU H13...

Страница 12: ...acles do not exist near the air inlet and air outlet Place where the air outlet may not be exposed to a strong wind Place surrounded at four sides are not suitable for installation A 1m or more of ove...

Страница 13: ...Installation Procedure 3 Installation dimension Unit mm 12 Installation of Outdoor Unit YUDA060 580 25 1250 948 380 340...

Страница 14: ...l not to let foreign matters such as sands enter the pipe 4 Piping connection method Forced fastening without centering may damage the threads and cause a gas leakage Model One way piping length Verti...

Страница 15: ...M g additional refrigerant per meter That is Refrigerant charging amount L 5m x 45 g m Air Tightness Test When pressurizing for 24 hours a variation of 1 C in the ambient temperature will cause a var...

Страница 16: ...the inspection of gas leakge No gas leakage In case of gas leakage tighten parts of pipe connection If leakage stops then proceed the step 6 If it does not stop gas leakage discharge whole refrigerant...

Страница 17: ...broken please change it with the type of T3 15A 250VAC But for YUDA060 the type is T6 3A 250VAC The wiring method should be in line with the local wiring standard The power cable and connecting cable...

Страница 18: ...RIC POWER IS SUPPLIED BE SURE TO EXECUTE OFF OPERATION BEFORE ELECTRIC POWER IS DISCONNECTED FOR SERVICING This unit has a function of automatic restart system after recovering power stoppage 1 Before...

Страница 19: ...Troubleshooting 18...