Safety Precautions

Be sure to conform with the following important Safety Precautions.

Carefully read the following information in order to operate the air conditioner correctly.

If any abnormal phenomena is found

(e. g.smell of firing), please cut off

the power supply immediately, and

contact the dealer to find out the

handling method.

In such case, to continue using the conditioner will damage

the conditioner, and may cause electrical shock or fire

hazard.

Don't dismantle the outlet of the

outdoor unit.

The exposure of fan is very dangerous

which may harm human beings.

Symbols used in the illustrations

:Indicates an action that must be avoided.

:Indicates that important instructions must be followed.

:Indicates a part which must be grounded.

:Beware of electric shock (This symbol is displayed on the main unit label.)

After reading this handbook, hand it over to those who will be using the unit.

The user of the unit should keep this mamual at hand and make it available to those who will be performing repairs or

relocating the unit. Also, make it available to the new user when the user changes hands.

Below are listed three kinds of Safety Precautions and Suggestions.

Incorrect operations may result in severe consequences of death or serious injuries.
Incorrect operations may result in injuries or machine damages; in some cases may

cause serious consequences.

INSTRUCTIONS: These information can ensure the correct operation of the machine.

After a long time use of air-conditioner

the base should be checked for any

damages.

If the damaged base is not repaired, the

unit may fall down and cause accidents.

When need maintenance and repairment,

call dealer to handle it.

Incorrect maintenance and repairment

may cause water leak, electrical shock

and fire hazard.

Air-conditioner can't be installed in the environment with

inflammable gases because the inflammable gases near

air-conditioner may cause fire hazard.

Please let the dealer be responsible for installing the

conditioner. Incorrect installation may cause water leak,

electrical shock and fire hazard.

Connect earthing wire.

Earthing wire should not be connected to the gas

pipe, water pipe, lightning rod or phone line,

incorrect earthing may cause shock.

Use discharge pipe correctly to ensure efficient discharge.

Incorrect pipe use may cause water leaking.

Installed electrical-leaking circuit breaker.

It easily cause electrical shock without circuit breaker.

Call the dealer to take measures to prevent the refrigerant

from leaking.

If conditioner is installed in a small room, be sure to take

every measure in order to prevent suffocation accident

even in case of refrigerant leakage.

When conditioner is installed or reinstalled, the dealer should

be responsible for them.

Incorrect installation may cause water leaking, electrical

shock and fire hazard.

No goods or nobody is permitted to

placed on or stand on outdoor unit.The

falling of goods and people may cause

accidents.

Don't operate the air-conditioner with

damp hands.Otherwise it will be shocked.

Only use correctly-typed fuse.

May not use wire or any other materials

replacing fuse, otherwise it may cause

faults or fire accidents.

Earthing

switch off

!

WARNING
CAUTION

WARNING

WARNING

Содержание AWAU-YUDA060-H13

Страница 1: ...OUTDOOR UNIT INSTALLATION MANUAL EN Please read this manual carefully before using this air conditioner Please keep this manual safely for future use R410A AWAU YUDA060 H13...

Страница 2: ......

Страница 3: ......

Страница 4: ...be checked for any damages If the damaged base is not repaired the unit may fall down and cause accidents When need maintenance and repairment call dealer to handle it Incorrect maintenance and repai...

Страница 5: ...to run an abnormal cycle and abnormal cycle and cause the unit to burst In the event of a refrigerant gas leak provide adequate ventilation to the room If leaked refrigerant gas is exposed to a heat...

Страница 6: ...at flares and flange connections Use liquid refrigerant to charge the system Charge the unit with gas refrigerant will cause the refrigerant in the cylinder to change its composition and will lead to...

Страница 7: ...ling draining pipes follow the instructions in the manual and make sure that they properly drain water so as to avoid dew condensation If not installed properly they may cause water leaks and damage t...

Страница 8: ...Refrigerant charging Vacuum Gauze Checking vacuum degree Tools Materials Use Notes Charging Cylinder Refrigerant Charging Must not be used with R410 type units CAUTION Items to Be Checked 1 Verify the...

Страница 9: ...ess If a clutch type flare tool is used to machine flares on units that use R410A make the protruding part of the pipe between 1 0 and 1 5mm Copper pipe gauge for adjusting the length of pipe protrusi...

Страница 10: ...il from flowing back into the refrigerant circuit when the vacuum pump power is turned off power failure It is also possible to attach a check valve to the actual vacuum pump afterwards Standard degre...

Страница 11: ...10 Name of Parts Air inlet Air outlet Compressor Inside of unit YUDA060 YUDA060 will be used as brief model name in this manual AWAU H13...

Страница 12: ...acles do not exist near the air inlet and air outlet Place where the air outlet may not be exposed to a strong wind Place surrounded at four sides are not suitable for installation A 1m or more of ove...

Страница 13: ...Installation Procedure 3 Installation dimension Unit mm 12 Installation of Outdoor Unit YUDA060 580 25 1250 948 380 340...

Страница 14: ...l not to let foreign matters such as sands enter the pipe 4 Piping connection method Forced fastening without centering may damage the threads and cause a gas leakage Model One way piping length Verti...

Страница 15: ...M g additional refrigerant per meter That is Refrigerant charging amount L 5m x 45 g m Air Tightness Test When pressurizing for 24 hours a variation of 1 C in the ambient temperature will cause a var...

Страница 16: ...the inspection of gas leakge No gas leakage In case of gas leakage tighten parts of pipe connection If leakage stops then proceed the step 6 If it does not stop gas leakage discharge whole refrigerant...

Страница 17: ...broken please change it with the type of T3 15A 250VAC But for YUDA060 the type is T6 3A 250VAC The wiring method should be in line with the local wiring standard The power cable and connecting cable...

Страница 18: ...RIC POWER IS SUPPLIED BE SURE TO EXECUTE OFF OPERATION BEFORE ELECTRIC POWER IS DISCONNECTED FOR SERVICING This unit has a function of automatic restart system after recovering power stoppage 1 Before...

Страница 19: ...Troubleshooting 18...

Страница 20: ......

Отзывы: