Pipes connections
Connect the water outlet/inlet using pipes and couplings that are resistant to both the operating pressure and
the hot water temperature, which can reach 70°C.
Note
Do not use materials that cannot
withstand high temperatures
Do not use flexible pipes for unit connection.
Water filter (Provided by the customer)
The filter is extremely important: it helps to lockout any impurities in the water and avoid clogging the system and heat exchanger.
I
t must be installed immediately at the entrance to the water, in a position that is easily
accessible for cleaning.
The filter should never be re-moved.
Pressure reducer (Provided by the customer)
If the inlet water pressure is less than 0,2MPa (2bar), a pump should be installed at the water inlet.
For guarantee the safety usage of storage tank at the condition of water supply hydraulic higher than 0,65MPa
(6,5bar), a pressure reducer should be installed at the water inlet pipe
A calibration pressure of 3-4 bar (0,3-0,4 MPa) is advisable. Periodically check the pressure
Expansion vessel (Provided by the customer)
Be provided with an expansion tank proportioned to the boiler's
dimensions (you are advise to let the circulation be made by a
thermo technician).
To compensate the pressure variations and/or the water hammers
in the cold water network and to avoid water losses, it is
recommended to install an expansion vessel
An expansion tank allows the correct system pressure to be
maintained when the water temperature varies.
Safety valve (Provided by the customer)
Install all safety devices required by the local laws in force in the
countries where the unit is installed.
The manufacturer of the heat pump shall not be held responsible
for any damage caused by failure to comply with said laws.
Install the safety valve (7 Bar max) (0,7 MPa max) on the
outlet of the domestic hot water, which must be connected to
a suitable discharge. If this is not done and the valve trips
and the room is flooded, the manufacturer of the heat pump
shall not be held responsible.
The discharge pipe connected to the safety valve must be
installed and angled downwards to an adequate drain and
sheltered from freezing.
The pressure-relief device is to be operated regularly to remove
lime deposits and to verify that is not blocked.
See Maintenance section.
To the installation information refer to: Water system piping
OK
NO
NO
Dielectric joints (Provided by the customer)
In order to prevent the formation of galvanic couples between iron/copper (risk of corrosion), do not connect
the domestic hot water connection directly to the copper pipes.
Install a dielectric joint on the domestic hot water inlet and outlet pipes
⇒
The above devices must be installed downstream of the product, before hydraulic shut-offs, and said devices
must not be hydraulically shut-off either.
Note
Содержание AW-TDF Series
Страница 90: ...Parts unit 190 Description...
Страница 91: ...Parts unit 190 Description...
Страница 92: ...Parts unit 190 Description...
Страница 93: ...Parts unit 300 Description El ectr ical heate r...
Страница 94: ...Parts unit 300 Description...
Страница 95: ...Parts unit 300 Description...
Страница 129: ......
Страница 159: ......