12 RESIDUAL RISKS / DISPOSAL
General
In this section the most common situations are signalled. As the-
se cannot be controlled by the manufacturer these could be a
source of risk situations for people or things.
Danger zone
This is an area in which only an authorised operator may work.
The danger zone is the area inside the unit which is accessible
only with the deliberate removal of protections or parts thereof.
Handling
The handling operations, if implemented without all of the protec-
tion necesssary and without due caution, may cause the fall or
the tipping of the unit with the consequent damage, even serious,
to persons, things or the unit itself. Handle the unit following the
instructions provided in the present manual regarding the packa-
ging and in compliance with the local regulations in force.
Should the gas refrigerant leak please refer to the refrigerant
"Safety sheet".
Installation
An incorrect installation of the unit could cause water leaks, con-
densate accumulation, leaking of the refrigerant, electric shock,
bad functioning or damage to the unit itself.
Check that the installation has been implemented by qualified
technical personnel only and that the instructions contained in
the present manual and the local regulations in force have been
adhered to. The installation of the unit in a place where even
infrequent leaks of inflammable gas and the accumulation of this
gas in the area surrounding the area occur could cause explo-
sions or fires. Carefully check the positioning of the unit. The
installation of the unit in a place unsuited to support its weight
and/or guarantee adequate anchorage may cause the fall or the
tipping of the unit with the consequent damage to things, people
or the unit itself. Carefully check the positioning and the ancho-
ring of the unit.
Easy access to the unit by children, unauthorised persons or ani-
mals may be the source of accidents, some serious.
Install the unit in areas which are only accessible to authorised
person and/or provide protection against intrusion into the dan-
ger zone .
General risks
Smell of burning, smoke or other signals of serious anomalies
may indicate a situation which could cause damage to people,
things or the unit itself. Electrically isolate the unit (yellow-red
isolator).
Contact the authorised service centre to identify and resolve the
problem at the source of the anomaly.
Accidental contact with exchange batteries, compressors, air deli-
very pipes or other components may cause injuries and/or burns.
Always wear suitable clothing including protective gloves to work
inside the danger zone.
Maintenance and repair operations carried out by non-qualified
personnel may cause damage to persons, things or the unit itself.
Always contact the qualified assistance centre.
Содержание AW-TDF Series
Страница 90: ...Parts unit 190 Description...
Страница 91: ...Parts unit 190 Description...
Страница 92: ...Parts unit 190 Description...
Страница 93: ...Parts unit 300 Description El ectr ical heate r...
Страница 94: ...Parts unit 300 Description...
Страница 95: ...Parts unit 300 Description...
Страница 129: ......
Страница 159: ......