10
MT- S
2.4GHZ FH4T RADIO SYSTEM USER'S GUIDE
T R
Telemetry System with Sanwa Synchronized Link Support
TRANSMITTER AND RECEIVER OVERVIEW DIAGRAM DESCRIPTIONS
GENERAL
Throttle Trigger Position Adjustment Screw:
Used to adjust the position of the Throttle Trigger either forward or backward.
Trim Switch:
The transmitter features three separate Trim Switches positioned around the Steering Wheel (Trm1, Trm2 and
Trm3). Each Trim Switch is programmable and will perform a different function depending on what function is assigned to it.
For example, Trm1 and Trm2 can be used to adjust steering and throttle Trim and Trm3 can be used to adjust steering Dual Rate.
UP Key:
Pressing the UP Key
scrolls between the STATUS and TELEMETRY screens, scrolls the Programming Cursor RIGHT or
UP and Increases Programming Values.
Wrist Strap Anchor:
Used to attach the wrist strap anchor to the transmitter.
TRANSMITTER LED CONDITION INDICATOR AND WARNING ALARMS
GENERAL
The MT-S is equipped with several different Audible Warning Alarms to warn you of an abnormal transmitter condition. In
addition, the LED Condition Indicator is used to indicate various conditions at a glance.
LED Condition Indicator
The LED Condition Indicator is used to indicate various transmitter conditions at a glance. Some of the conditions indicated by
the LED may also be accompanied by an audible alarm and/or and on-screen warning.
ON
Flash Rapidly
Flash Rapidly, Then Pause
Flash Slowly
Flash Rapidly, Then Pause
Flash Rapidly, Then Pause
Flash Rapidly
Flash Rapidly
Flash Slowly
Flash Slowly
TRANSMITTER STATUS
LED
RF Output Signal
Anti-Lock Braking Function Active
Throttle Offset Function Active
Low Voltage Alert Alarm Active
Telemetry Alarm Active
Inactivity Alarm Active
Low Voltage Limit Alarm Active
Over Voltage Alarm Active
RF Binding - Sending Bind Code
Telemetry Logger Function Active
REMARK
Normal Operation
Press ENTER or BACK Key to Cancel
Press ENTER or BACK Key to Cancel
Replace Batteries
Battery Voltage Too High
Audible Warning Alarms
The audible alarms listed below and on the next page may also be accompanied by an on-screen warning.
Inactivity (Power ON) Alarm:
The Inactivity Alarm will sound if the transmitter is left on for a period of 10 minutes without any control input from the user. This
alarm alerts you to prevent unwanted draining of the transmitter battery.
To clear this alarm, either turn the transmitter OFF or press the ENTER or BACK key.
Over Voltage Alarm:
The Over Voltage Alarm will sound if the transmitter battery voltage is greater than 9.6 volts.
To clear this alarm, turn the transmitter OFF and replace the transmitter battery with one that when fully charged does not
exceed 9.6 volts.
Low Voltage Alert Alarm:
The Low Voltage Alert alarm will sound when the transmitter batteries reach the Low Voltage Alert alarm voltage value
programmed in the SYSTEM > ALARM menu. The alarm will sound each time the transmitter battery voltage Decreases by 0.1 volt.
To clear this alarm, press the ENTER or BACK key.
Low Voltage Limit Alarm:
The Low Voltage Limit alarm will sound when the transmitter batteries reach the Low Voltage Limit alarm voltage value
programmed in the SYSTEM > ALARM menu.
This alarm can only be cleared by turning the transmitter OFF and replacing or recharging the transmitter batteries.
Telemetry Alarm:
The Telemetry alarm will sound when the Temperature 1 Alert alarm, Temperature 2 Alert alarm and/or the Voltage Alert
alarm reach the Alert value programmed in the SYSTEM > TELEMETRY menu.
To clear this alarm, press the ENTER or BACK key.