- CYPRES 2 User’s Guide -
page 23
The processing unit must be placed into the pouch
in such a way that the cables lie flat on the bottom
of the pouch. No tension must be placed on the
control unit cable and cutter cable(s).
Any excess cable is stowed in the flat part of the
pocket underneath the velcro-adjustable flap. If
you are stowing both the thinner cutter cable and
the thicker control unit cable, be sure to place the
thicker cable so that it lies on top of the thinner
one. Cables should be placed in a circle in order
to avoid twists. Always avoid pulling, bending,
twisting, or kinking the cables.
CYPRES 2 can easily be removed by the owner. Do
not pull on the cables - instead, push the processing
unit, cutter and control unit from their keepers.
right
Wrong
- Cables not flat on
bottom
- Unit is inserted
upside down
- Thin cable on top
of thicker cable
- Cable is bent
Poor installation can impede the proper opening of
the container.
This may cause injury or death. Never install a
CYPRES 2 by trial and error.