Data applicable to all Non Military CYPRES:
Length, width, height of the processing unit .................... approx. 88 x 57 x 28.5mm
Length, width, height of the control unit ............................. approx. 65 x 18 x 6.5mm
Length, diameter of the release unit ........................................... approx. 43 x 8.0mm
Cable length of the release unit ......................................................... approx. 500mm
Storing temperature ................................................................ +71° to -25° centigrade
Working temperature ........................................................... +63° to -20° centigrade *
Maximum allowable humidity ................................................. up to 98 % rel. humidity
Altitude adjustment limits ................................................................ ±500m or ±1500ft
Operating range above sea level ...... -500m to +8000m (-1600 feet to +26000 feet)
Functioning period ......................................................................................... 14 hours
Battery life ..................................................... approx. 500 jumps or approx. 2 years
Maintenance .......................... 4 and 8 years from date of manufacture ± 3 months
Total lifetime ..................... 12 years from date of manuf 3 months maximum
Special data for the EXPERT CYPRES:
Cable length of control unit ................................................................ approx. 670mm
Volume ............................................................................................... approx. 165cm³
Weight ............................................................................................. approx. 262 gram
Activation altitude ................................................... approx. 225m (approx. 750 feet)
Activation speed ............................................................
≥
approx. 35m/sec (78mph)
Special data for the STUDENT CYPRES:
Cable length of control unit .............................................................. approx. 1000mm
Volume ............................................................................................... approx. 170cm³
Weight ............................................................................................. approx. 279 gram
Activation altitude ................................................... approx. 225m (approx. 750 feet)
Activation speed ............................................................
≥
approx. 13m/sec (29mph)
Special data for the TANDEM CYPRES:
Cable length of control unit ................................................................ approx. 670mm
Volume ............................................................................................... approx. 165cm³
Weight ........................................................................................... approx. 262 gramm
Activation altitude ................................................. approx. 580m (approx. 1900 feet)
Activation speed ............................................................
≥
approx. 35m/sec (78mph)
The above data apply to the civilian version.
* These temperature limits do not mean the outside (ambient)
temperatures but temperatures inside the unit.
Therefore, these limits won't have any meaning until the unit itself has reached the
temperature in question. In actual fact, the limits will rarely ever be reached because
of the insulating properties of the nylon pocket and the recommended installation
location.