MILITARY CYPRES USER'S GUIDE
Airtec GmbH
Page 47
8.2
Packing of two-pin reserve containers
These points apply when packing a two-pin container in which CYPRES has been
installed:
•
Use only original silicone impregnated CYPRES loops (delivered with the unit).
The use of thicker loops could prevent proper functioning of the system.
•
Impregnate Running loops completely with silicone. If two one-pin loops are
used the looped ends of the CYPRES loops should be impregnated with silicone
except for 1/2" next to the disc.
•
Make sure that the loop can run freely through the double bottom of the container.
•
If the release unit is not mounted on the bottom of the container, lengthen the
loop approx. two centimeters (2cm) to allow for the added thickness.
•
Use only the original CYPRES pull-ups (delivered with the unit.)
Except for these instructions, follow all other regular packing procedures described by
your system manufacturer.