background image

En-3

(1)  Install the indoor unit on a place having a suf

fi

 cient strength so that it withstands 

against the weight of the indoor unit.

(2)  The inlet and outlet ports should not be obstructed; the air should be able to blow all 

over the room.

(3)  Leave the space required to service the air conditioner.
(4)  Install the unit where connection to the outdoor unit is easy. 
(5)  Install the unit where the connection pipe can be easily installed. 
(6)  Install the unit where the drain pipe can be easily installed.
(7)  Install the unit where noise and vibrations are not ampli

fi

 ed. 

(8)  Take servicing, etc., into consideration and leave the spaces. Also install the unit 

where the 

fi

 lter can be removed.

(9)  Do not install the unit where it will be exposed to direct sunlight.

]1

3.2. Installation dimension

2-3/8 in. (60 mm) or over

Left side 1-31/32 in. 
(50 mm) or over

59-1/16 in. 
(1500 mm) or 
over

5 ft. 10-7/8 in. 
(1800 mm) or 
over

Wall hook bracket

Right side 7-7/8 in. 
(200 mm) or over

For the drain hose 
extension, use a 
drain hose with 
a 5/8 in. (16 mm) 
inside diameter.

]1

3.3.  Installation the unit

 WARNING

Install the air conditioner in a location which can withstand a load of at least 5 times 
the weight of the main unit and which will not amplify sound or vibration. If the 
installation location is not strong enough, the indoor unit may fall and cause injuries.

The piping can be connected in the 7 directions indicated by 

1

2

3

4

5

6

 and 

7

 

5

 

Left piping

2

 Right 

piping

3

 Bottom piping

6

 Center piping

                                

4

 Left bottom piping

7

 Left rear piping

1

 Rear piping

3.3.1. Installing the wall hook bracket

 WARNING

If the wall pipe is not used, the cable interconnecting the indoor and outdoor units may 
touch metal and cause electric leakage.

[Installation directly to a wall]

Refer to Fig. A for the installation hole dimensions of the wall hook bracket.

Before fastening the wall hook bracket to the wall with the screws, level it by tapping the 
hook at the center of bracket to the wall with the handle of a screwdriver.
(1)  Fasten the wall hook bracket to the wall with 6 or more screws and anchor bolts 

through the holes near the outer edge of the bracket.

 

(Do not install the wall hook bracket at only 1 place or at an angle.)

(2)  For a concrete wall, embed anchor bolts (13/32 in. (10 mm) dia.) into the wall at the 

wall hook bracket holes. 

 

(Allow the anchor bolts to stick out at least 23/32 in. (18 mm) from the wall. Use 2 
bolts for 

fl

 at concrete wall and 4 bolts for blister concrete wall.)

(3)  Install the nuts to the anchor bolts through the wall hook bracket. 
(4)  Finally tighten the bolts and wood screws after con

fi

 rming, using the level indicator, 

that the clamp is horizontal.

 WARNING

Install the wall hook bracket level, both horizontally and vertically. If the wall hook 
bracket is tilted, wa ter will drip to the 

fl

 oor.

As the weight of the indoor unit is 33 to 40 lbs. (15 to 18 kg), it should be installed 
after properly examining the place where it is in tended to be in stalled. If the place is 
not strong enough, a plank or girder should be used to make the place suf

fi

 ciently 

strong so that the wall can support the weight.

Fig. A

17-9/32 (439)

4-13/16

(122)

2-15/16

(75)

2-15/16

(75)

1-15/32

(37)

Ø 3-5/32 

(80)

Ø 2-9/16 (65)

Ø 3-5/32 (80)

17-1/4 (438)

15-5/8 (397)

39-9/32 (998)

6-11/16

(170)

5-1/8

(130)

1-1/32 × 7/16

(26 × 11)

1-1/32 × 7/16

(26 × 11)

23/32 × 7/16

(18 × 11)

23/32 × 7/16

(18 × 11)

13/16 × 3/16

(21 × 5)

3/16 × 23/32

(5 × 18)

3/16 × 1-31/32

(5 × 50)

1/2 × 3/16

(13 × 5)

6-25/32

(172)

5-1/4

(133)

4-31/32

(126)

25/32 (20)

15-1/4 (387)

5/8 (16)

15-3/4 (400)

9-9/16 (243)

4-7/16 (113)

15/32 (12)

15/32 (12)

10-19/32 (269)

12-19/32 (320)

1-23/32 (44)

1/2 (13)

15-7/8 (149)

7-3/4 (197)

1-3/16 (30)

10-23/32 (272)

[UNIT: in. (mm)]

UNIT centre

(UNIT size)

Piping inlet

hole

Outline of UNIT

hole

hole

hole

hole (14 places)

hole (14 places)

Piping inlet

hole (3 places)

hole (4 places)

hole for tapping screw

(UNIT

 size)

Wall hook bracket

Tapping screw (big) 

3.3.2.  Cutting the hole in the wall for the connecting piping

 WARNING

If the wall pipe is not used, the cable may touch metal and cause electric leakage.

(1)  Cut a 3-5/32 in. (80 mm) diameter hole in the wall at the position shown in Fig. B.
(2) For 

1

 Rear piping and 

7

 Left rear piping, cut the hole to a point of intersection of 

center marks (Fig. B).

 For 

2

 Right piping and 

5

 Left piping, cut the hole at least 13/32 in. (10 mm) below 

the holes for the rear piping and left rear piping for the drain water to 

fl

 ow freely (Fig. B).

 For 

6

 Center piping, cut a hole in the lower, center section of the wall hook bracket. 

 

(Refer to Fig. A. Do not cut a hole outside of the indoor unit outline.)

(3)  Cut the hole so that the outside end is lower 3/16 to 13/32 in. (5 to 10 mm) than the 

inside end.

(4)  Always align the center of the wall hole. If misaligned, water leakage will occur.
(5)  Cut the wall pipe to match the wall thickness, stick it into the wall cap fasten with 

vinyl tape, and stick the pipe through the hole. (The connection pipe is supplied in the 
installation set.)

(6)  For left piping and right piping and center piping, cut the hole a little lower so that 

drain water will 

fl

 ow freely.

Fig. B

Wall hook bracket

3-5/32 in. 

(80 mm) 

dia. hole

(For 

2

 

Right 

piping)

Lower

3-5/32 in. 

(80 mm) 

dia. hole

Center mark

Lower

13/32 in. 

(10 mm) 

or more

(For 

5

 

Left 

piping)

(For 

1

 

Rear 

piping)

(For 

7

 

Left rear 

piping)

13/32 in. 

(10 mm) 

or more

Fasten with 
vinyl tape

Wall cap*

(Wall pipe)*

(Inside)

Wall

(Outside)
*Field supply

3/16 to 13/32 in. 
(5 to 10 mm) low

9373370154-01_IM.indb   3

9373370154-01_IM.indb   3

3/14/2012   3:03:51 PM

3/14/2012   3:03:51 PM

Содержание ASUB18RLAV

Страница 1: ...ll Mounted Type APPAREIL INTÉRIEUR Type montage mural UNIDAD INTERIOR Tipo Montado en Pared UNIDADE INTERIOR Tipo montado na parede For authorized personnel only Pour le personnel agréé uniquement Sólo para personal de mantenimiento autorizado Apenas para técnicos de assistência autorizados TM PART NO 9373370154 ASUB18RLAV ASUB24RLAV ...

Страница 2: ...re opening the refrigerant valves When Servicing Turn the power OFF at the main circuit breaker panel before opening the unit to check or repair electrical parts and wiring Keep your fingers and clothing away from any moving parts Clean up the site after you finish remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced After installation explain c...

Страница 3: ...1 For indoor unit installation Cloth tape 1 For indoor unit installation Name and Shape Q ty Application Tapping screw Big M4 25 mm 8 For wall hook bracket installa tion Air cleaning filter 2 Air cleaning filter frame 2 Drain hose Insulation 1 For installing drain hose Connecting cable 2 For wired remote controller cable connection and simple remote controller cable connection Adapter cable Remote...

Страница 4: ...wood screws after confirming using the level indicator that the clamp is horizontal WARNING Install the wall hook bracket level both horizontally and vertically If the wall hook bracket is tilted water will drip to the floor As the weight of the indoor unit is 33 to 40 lbs 15 to 18 kg it should be installed after properly examining the place where it is intended to be installed If the place is not...

Страница 5: ...imension B 0 015 0 4 in mm Flare tool for R410A clutch type 1 4 6 35 0 to 0 020 0 to 0 5 11 32 9 1 3 8 9 52 17 32 13 2 1 2 12 70 21 32 16 6 5 8 15 88 25 32 19 7 3 4 19 05 15 16 24 0 When using conventional R22 flare tools to flare R410A pipes the dimension A should be approximately 0 020 in 0 5 mm more than indicated in the table for flaring with R410A flare tools to achieve the specified flaring ...

Страница 6: ...t remove the flare nut from the indoor unit pipe until immediately before connecting the connection pipe To prevent breaking of the pipe avoid sharp bends If the pipe is bent repeatedly at the same place it will break For 1 Rear piping 2 Right piping and 3 Bottom piping Install the indoor unit piping in the direction of the wall hole and bind the drain hose and pipe together with vinyl tape Instal...

Страница 7: ...es with wiring holders Improper connections either in the wiring or at the ends of the wiring can cause a malfunction electric shock or fire Always fasten the outside covering of the connection cable with the cable clamp If the insulator is chafed electric discharge may occur Securely install the electrical box cover on the unit An improperly installed electrical box cover can cause serious accide...

Страница 8: ... for the terminal screw tightening torques 7 Please do not fix 2 power supply cables with 1 screw Sleeve Screw with special washer Screw with special washer Ring terminal Cable Cable Terminal block Ring terminal Ring terminal Strip 13 32 in 10 mm WARNING Use ring terminals and tighten the terminal screws to the specified torques otherwise abnormal overheating may be produced and possibly cause hea...

Страница 9: ...ith appropriate external dimension depending on the number of cables to be installed The wire connection should be separate from the power cable line Input selection Use either one of these types of terminal according to the application Both types of termi nals cannot be used simultaneously Voltage terminal CN6 When a power supply must be provided at the input device you want to connect use the vo...

Страница 10: ...p Selection method of functions Start Stop mode or Emergency stop mode Forced stop mode can be selected with function setting of indoor unit 1 Make the power supply DC 12 to 24 V Select a power supply capacity with an ample surplus for the connected load Do not impress a voltage exceeding 24 V across pins 1 2 and 1 3 a The allowable current is DC 5 10 mA Recommended DC 5 mA Provide a load resistan...

Страница 11: ...ctor to join field cable and wire kit wire Connect the wire with connecting wire with solder Important Be sure to insulate the connection between the wires Option parts External input output wire Insulated connection Field supply Input No Voltage terminal CN17 Controller PCB Input Voltage terminal CN6 Output terminal CN16 CN17 CN16 CN6 Connecting cables Controller PCB Cable tie Field supply 7 FIEL...

Страница 12: ...tch REF AD 10 Factory setting 0 In the case of multiple refrigerant systems set REF AD SW as shown in the Table A for each refrigerant system Set to the same refrigerant circuit address as the outdoor unit Setting Setting range Type of switch Indoor unit address 0 63 Setting example 2 IU AD 10 IU AD 1 Refrigerant circuit address 0 99 Setting example 63 REF AD 10 REF AD 1 Table A Address Rotary Swi...

Страница 13: ... 00 Enable Enable or disable the filter indicator Setting 02 is for use with a central remote controller 01 Disable 02 Display only on central remote controller Horizontal swing airflow direction 24 00 Default Adjust the horizontal swing airflow direction For horizontal swing equipped mod els 01 Left half 02 Right half Cool air tem perature trigger 30 00 Default Adjust the cool air trigger tempera...

Страница 14: ...umber 2 OPERATION indicator lamp Green TIMER indicator lamp Orange FILTER indicator lamp Red 11 sec 10 sec 9 sec 1 cycle 12 sec ON OFF 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s ON OFF ON OFF 8 FINISHING Before performing this section perform a sealing test Refer to the installation Manual for the outdoor unit 1 8 1 Connection pipe cable and drain hose Insulate the drain hose if n...

Страница 15: ...smission and Re mote controller cable Drain hose Saddle Pipe Outside wall cap Wall Outdoors Sealer putty Field supply GOOD Drain hose Saddle Lifted up Wave End in water PROHIBITED 1 8 2 Installing front cover Fix the indoor unit 1 Please remove the spacer Indoor Unit Remove Spacer 2 Hook the fittings of the indoor unit to the 2 bottom hooks while lowering the unit and pushing it against the wall B...

Страница 16: ... burn damage Is the indoor unit earthed grounded Short circuit Is the connection cable the specified thickness No operation heat or burn damage Are the inlets and outlets free of any obstacles No cooling No heating Does start and stop air con ditioner operation by remote controller or external device No operation After installation is completed has the proper operation and handling been explained ...

Страница 17: ......

Отзывы: