background image

En-4

3.3.5  Forming the drain hose and pipe

 

CAUTION

Insert drain hose and drain cap securely. Drain should slope down to avoid water leak-
age.

When inserting the drain hose, no other material than water should be applied. Applica-
tion of other material than water will cause deterioration of the hose, and may cause 
water leakage.

After you remove a drain hose, be sure to attach the drain cap.

When you secure the piping and drain hose with tape, arrange the drain hose so that it 
is at the bottom of the piping.

For drain hose piping in low temperature environment, you need to apply freeze protec-
tion to prevent a frozen drain hose.
After cooling operation is performed in low temperature environment, (when outdoor 
temperature under 32°F (0°C),) water in the drain hose could be frozen. Frozen drain 
water will block the water flow in the hose, and may cause water leakage at the indoor 
unit.

[For (A) Rear piping, (B) Right piping and (C) Bottom piping]

(1)  Install the indoor unit piping in 

the direction of the wall hole 
and bind the drain hose and 
pipe together with vinyl tape.

(2)  Install the piping so that the 

drain hose is at the bottom.

(3)  Wrap the pipe of the indoor unit 

that visible from the outside 
with decorative tape.

(4)  For right or bottom outlet 

piping, cut off the piping outlet 
cutting groove with a hacksaw.

Bind with vinyl tape

Bottom piping

Pipe (top)
Rear piping

Indoor unit drain hose 
(bottom)

[For (D) Left bottom piping, (E) Left piping and (F) Center piping, (G) Left rear 
piping]

 

CAUTION

Insert the drain hose and drain cap into the drain port, making sure that it comes in con-
tact with the back of the drain port, and then mount it. If the drain hose is not connected 
properly, leaking will occur.

(1)  Interchange the drain cap and the drain hose.

• For left outlet piping, cut off 

the piping outlet cutting groove 
with a hacksaw.

• Remove the drain cap by pull-

ing at the projection at the end 
of the cap with pliers, etc.

Left side

Right side

Drain cap

Drain hose

Drain hose removal and installation method of the 4/7/9 model

Removal

Installation

Screw

Drain hose

Drain fixture

Drain cock

Screw hole

Drain hose

Screw

Drain fixture

Remove the screw at the left 
of drain hose and pull out 
drain hose.

Vertically insert the drain hose toward the inside, so 
that the drain fixture can accurately align with the screw 
hole around the drain cock. After inserting and before 
replacing, reinstall and fix the removed screws.

Installing the drain cap

Drain cap

Drain cock

No gap

Hexagonal 
wrench

Use a hexagonal wrench 3/16 in (4 mm) at op-
posite side to insert the drain cap, till the drain cap 
contacts the tip of drain cock.

(2)  Align the marks on the wall hook bracket and shape the connection pipe.

For left piping and left rear piping, align the marks on the wall hook bracket and 
shape the connection pipe.

Alignment marks

Wall hook 
bracket

Connection 
piping

Connection pipe 
(Liquid pipe)

Connection pipe (Gas pipe)

4/7/9 model

Wall hook bracket

Tapping screw 
(accessory, 5 pcs)

30/36 model

Wall hook bracket

Tapping screw 
(accessory, 8 pcs)

3.3.3  Cutting the hole in the wall for the connecting piping

(1)  Cut a hole in the wall at the position shown in the following.
(2)  Cut the hole so that the outside end is lower (3/16 to 3/8 in (5 to 10 mm)) than the 

inside end.

(3)  Always align the center of the wall hole. If misaligned, water leakage will occur.
(4)  Cut the wall pipe to match the wall thickness, stick it into the wall cap, fasten the cap 

with vinyl tape, and stick the pipe through the hole.

(5)  For left piping and right piping, cut the hole a little lower so that drain water will flow 

freely.

4/7/9 model

Center mark

Center mark

2-9/16 (65) dia. hole

2-9/16 (65) dia. hole

Wall hook bracket

Unit: in (mm)

30/36 model

Center mark

Unit: in (mm)

Wall hook bracket

3-1/8 (80) dia. hole

3-1/8 (80) dia. hole

3/8 (10) 
or more

3/8 (10) 
or more

Lower

Lower

Attach the wall pipe

Fasten with vinyl 
tape

Wall cap*

Wall pipe*

(Inside)

Wall

(Outside)

* Locally 

purchased

3/16 to 
3/8 in 
(5 to 10 
mm) low

 

WARNING

If the wall pipe is not used, the 
cable interconnecting the indoor 
and outdoor units may touch 
metal and cause electric leakage.

3.3.4  Attach the drain hose insulation (30/36 model only)

• Wrap the insulation around the 

drain hose, making sure that 
there are no gaps.

• Attach the Insulation (Drain 

hose) to the drain hose.

Drain hose

Insulation (Drain hose) 
(Accessories)

9373370420-02_IM.indb   4

9373370420-02_IM.indb   4

2017/12/20   9:48:59

2017/12/20   9:48:59

Содержание ASUA4TLAV1

Страница 1: ...1 ASUB36TLAV1 TM Fran ais Espa ol MANUEL D INSTALLATION MANUAL DE INSTALACI N UNIT INT RIEURE Type montage mural UNIDAD INTERIOR Tipo montado en pared Pour le personnel agr uniquement nicamente para p...

Страница 2: ...k or repair electrical parts and wiring Keep your fingers and clothing away from any moving parts Clean up the site after you finish remembering to check that no metal scraps or bits of wiring have be...

Страница 3: ...ing a vacuum pump adapter A conventional vacuum pump can be used by installing a vacuum pump adapter Be sure that the pump oil does not back flow into the system Use one capable for vacuum suction of...

Страница 4: ...f the human sensor 30 36 model only CAUTION Do not hit or push the human sensor This may lead to damage or malfunction Do not touch the human sensor Any scratches or dirt may lead to incorrect detecti...

Страница 5: ...n hose Screw Drain fixture Remove the screw at the left of drain hose and pull out drain hose Vertically insert the drain hose toward the inside so that the drain fixture can accurately align with the...

Страница 6: ...pipes Failure to do so may cause water leaks Use heat insulation with heat resistance above 248 F 120 C Reverse cycle model only In addition if the humidity level at the installation location of the...

Страница 7: ...the flare nut cannot tightened smoothly If the flare nut is forced to turn the threads will be damaged Do not remove the flare nut from the indoor unit pipe until immediately before connect ing the co...

Страница 8: ...p B For strand wiring 1 Use ring terminals with insulating sleeves as shown in the figure below to connect to the terminal block 2 Securely clamp the ring terminals to the cables using an appropriate...

Страница 9: ...h installation manual 5 4 Wiring 1 Open the intake grille Refer to 8 FRONT PANEL REMOVAL AND INSTALLATION 2 Remove the wire cover and remove the cable clamp 4 7 9 model 30 36 model Screw Cable clamp W...

Страница 10: ...tached to wire kit connector 2 Remove insulation from field supplied cable Use crimp type insulated butt connector to join field cable and wire kit wire 3 Connect the wire with connecting wire with so...

Страница 11: ...hod of functions Operation Stop mode or Emergency stop mode Forced stop mode can be selected with function setting of indoor unit Forced thermostat off function Edge input only Connector Input signal...

Страница 12: ...1 0 1 1 0 1 2 0 2 2 0 2 3 0 3 3 0 3 4 0 4 4 0 4 5 0 5 5 0 5 6 0 6 6 0 6 7 0 7 7 0 7 8 0 8 8 0 8 9 0 9 9 0 9 10 1 0 10 1 0 11 1 1 11 1 1 12 1 2 12 1 2 99 9 9 63 6 3 Do not set the indoor unit address I...

Страница 13: ...For details of the connection ter minal functions see the Design Technical Manual 01 Mode 1 02 Mode 2 03 Mode 3 04 Mode 4 05 Mode 5 06 Mode 6 07 Mode 7 08 Mode 8 Control switching of external heaters...

Страница 14: ...F Center piping and G Left rear piping butt the connection pipe heat insulation and indoor unit pipe heat insulation together and bind them with vinyl tape so that there is no gap A Rear B Right and C...

Страница 15: ...f any obstacles No cooling No heating Does start and stop air conditioner operation by remote controller or external device No operation After installation is completed has the proper operation and ha...

Страница 16: ...r 4 1 Indoor unit room temp thermistor error 4 2 Indoor unit heat ex temp thermistor error 4 4 Human sensor error 5 1 Indoor unit fan motor 1 error 5 2 Indoor unit coil expan sion valve error 5 3 Indo...