Warning:
To avoid electrical or fire hazard, ensure that the connection to the GPS is
made prior to connecting the BSDU to the power supply.
The GPS-to-BSDU cable setup is as follows:
Cable: 12-pin conductor cable for RS-422 serial interface (multipair overall shielded -- 22
AWG) of 5, 15, or 30 meters in length depending on customer requirements
Connectors:
o
GPS side: RS-422 weathertight 12-pin plug (Deutsch MMP26C-2212S1)
o
BSDU side: 15-pin D-type male
o
Connector pinouts: The GPS connector receptacle contains 12 male contacts, as
displayed below:
GPS connector pinouts
The connector pinouts for the GPS-to-BSDU 12-pin cabling are described in the table below.