605-0000-742_MicroMAX_Hardware_Installation_Rev_G
32
shown, the MicroMAX pole-mounting bracket allows elevation between -18.5° and
26.3°.
b.
Adjust the horizontal position of the MicroMAX by rotating it about the pole, and then
tightening the nuts of the U-bolts.
Note:
A thread-locking compound must be used to prevent the bolts from working loose.
MicroMAX positioning is obtained in two planes by adjustment of the mounting bracket assembly as
shown below.
It is important to provide strain relief and drip loop for Cat-5 cables. Create a drip loop and strain
relief using cable tie, to tie cable to pole, as displayed in the figure below: