INSTALLATION
Electric power cable
●
The power cable is not included. It has to be procured before
the installation. Choose the type and thickness of the cable
according to the unit’s maximum consumption and the specific
requirements of the place of installation.
TECHNICAL INFORMATION
●
The electrical parameters can be found on the manufacturer's
labels inside and on the side of the unit (Fig. 1).
ELECTRIC INSTALLATION AND WIRING
CAUTION!
•
The main power supply must be turned off before
working on the internal parts of the unit.
•
The electrical installation must be done pursuant to
the technical documentation and by a certified electri-
cian. The installation might be done by a professional
with qualifications in electricity. The manual must ob-
served, together with the laws and regulations appli-
cable in the country.
•
The wiring diagrams in the product have a higher
priority than those in manual. Before the installa-
tion, check that the indication of the terminals corre-
sponds to the wiring connection diagram. In case of
doubt, contact the supplier and do not connect the
unit under any circumstances.
•
The unit must be connected to the main power source
with an isolated cable with a heat resistance in com-
pliance with the diameter and the applicable laws and
regulations of the country.
•
Any altering or changes to the internal connections
of the unit are forbidden and may result in the loss of
warranty.
•
Only the use of original accessories guarantees the
correct function of the unit.
All the unit's electrical circuits must be connected through an
earth leakage breaker according to the current model.
The unit must be connected in a way that it can be disconnected
from the power supply with one piece.
Table of minimum sizes of breakers according to the model of
heat recovery unit.
Recommended minimum values of the circuit breakers:
Circuit breakers
Susurro 700
13A (1F)
Susurro 700
10A (3F)
Susurro 700
13A (1F)
Accessories
Connect the electric accessories of the unit to the connecting
terminal, as shown in the diagram and the indications of the
terminals.
Product designation
Serial number
• U = Voltage
• f = Frequency
• n = Speed
• ph = Phase
• av = Air output
• I = Total current
• P = Output
• m = weight
• IP = IP cover
• ver = designation for producer
(Fig. 1) Location of the label and explanation of each part.