background image

page 8

FILTER MAINTENANCE

WARNINGS

Do not use any cleaning oil with volatile or harsh substance and metal brush while cleaning 

the air filter as it will damage the surface of the air filter.

When performing cleaning work, please switch off all power supplies to avoid electric shock.

Always wear protective hand gears when performing cleaning to avoid personal injuries.

Always beware of objects below the feet and falling dirty particles when performing cleaning 

at a high position from ground.

Do not use heating equipment to dry up the unit after cleaning as it will deform the unit’s 

shape and damage its function.

MAINTENANCE OF THE HIGH EFFICIENCY COMBO FILTER

The “Filter Change Indicator” will indicate the need for the 

change of air filter. Irregular service and maintenance of 

the air filter will reduce the functionability of the air filter, 

or lead to malfunction or even damage.

Set the frequency of the air filter maintenance according 

to the usage capacity within the given environment. We 

recommend a regular cleaning every 30 days, and a 

replacement of the air filter every 180 days. If the usage 

is heavy, the cleaning and replacement period can be 

adjusted accordingly. 

Filter

Change

Temperature

Wind

Speed

Modes

PLUS                   DIRECT                 SMART                BYPASS

HIGH                      MID                       LOW                   SLEEP

Filter Change

Indicator

About the Air Filter Lifespan

1. The need for change of the High Efficiency Combo Filter of every unit may differ depending on the kind of 

    environment and the usage capacity. Please replace the filter when necessary.

2. Set the frequency of the air filter replacement according to the usage capacity and environment settings.

3. The air flow and air capture efficiency may deteriorate due to the kind of environment usage and over time. 

    If the High Efficiency Combo Filter arrow indicator become blacken entirely, please change and replace the 

    filter immediately.

4. In the event of environment with reasonably good conditions, where air particles with the diameter of less 

    than 2.5um and condensity of less than 50ug/m

3

, the accuracy of the sensory components may lead to a 

    major statistical discrepancy of the test reading, which may cause the above efficiency performance to 

    decrease. (The manufacturer uses TSI8530 as the standard measuring equipment) 

Metal Filter
High Efficiency Combo Filter
Activated Carbon Filter

CLEANING 

 

 

            REPLACEMENT

Once every 30 days
Once every 30 days
Once every 30 days

Not needed

As and when required by the Filter Change Indicator
As and when required by the Filter Change Indicator

Cleaning & Replacing the Air FIlter

Please follow the below steps accordingly when 

cleaning the air filter.

1. Shut down all power supply

2. Loosen the Inspection Door.

Содержание FS-150

Страница 1: ...FRESH AIR SUPPLY VENTILATOR FS 150 USER MANUAL ...

Страница 2: ... Products Specification 1 Dimension Spare Parts 1 Packing List 2 IImportant Notice 2 Safety Precautions 3 Inspection Door Settings Check 4 Installation Guides 4 Filter Maintenance 8 Troubleshooting 10 Customer Service 10 ...

Страница 3: ...L SPEED POWER AIR FLOW STATIC PRESSURE WEIGHT W m3 h Pa kg RATED VOLTAGE V FS 150 240 50 RATED FREQUENCY Hz HIGH MID LOW 68 54 50 250 170 135 185 160 135 OPERATION MODES WATER PROOF LEVEL IPX2 9 5 NOTE 1 The units of Air Flow Voltage and other variances are measured under the condition of zero Static Pressure 2 The measurement of Air Flow are obtained under the strictest monitoring within our rese...

Страница 4: ...modes of the unit High Mid Low Stop with the help of the integrated temperature sensor to eliminate the likelihood of discomfort caused by the variances between indoor and outdoor temperature Hence it is absolutely normal that the operating modes of the unit may alter from time to time due to the change in temperature Under the normal circumstances of operating room temperature 10 40 the performan...

Страница 5: ...mpt on repairing the unit or any of its spare parts if there are any damages Ask for the help of the qualifies and trained professional for assistance WARNINGS PRECAUTIONS Do not place any foreign objects directly close to the air inlet or the air outlet of the unit Do not use open flames near the main unit as it may lead to possible high risk of fire hazard Do not place any foreign objects on the...

Страница 6: ...n weight of the unit The position of the 3 Hanging Screw Fastener are as indicated in the diagram 2 Installing the unit onto the Fastener Securely install the Screw Fastener layering loop and main screws optional by user use only M8 M10 types Main Screws Layering Loop Screw Fastener 3 Connect the Ducting Tightly secure the ducting to the connecting inlet or outlet and seal it with tapes The ductin...

Страница 7: ... Cloth Line 86 Box Control Kit Connect the Cloth line and the 86 Box Control Kit according to the Line Schematic Diagram on page 8 Copper Wire Connecting Earth Wire Fixed Cloth Line Unit in mm 86 Box Control Kit Wire Power Supply Wire Cap Earth Wire Live Wire Connecting Rod Screws 86 Box Control Kit Wire 86 Box Control Kit Wire B 86 BOX CONTROL KIT INSTALLATION 1 Remove the back cap a Use the Slot...

Страница 8: ...or and outdoor air quality is poor The PLUS mode can help to improve the overall air quality to enhance the cleanliness of the indoor air 1 Press the button to turn on the PLUS mode the wind default speed is set as HIGH To adjust the speed simply press the HIGH MID or LOW button 2 To turn off the PLUS mode press the button one more time to turn off Filter Change Temperature Wind Speed Modes PLUS D...

Страница 9: ...aner indoor air for all 1 Press the button to turn on the DIRECT mode the wind default speed is set as LOW 2 To turn off the SLEEP mode press the button one more time to turn off PRECAUTIONS The default air temperature indicated on the 86 Box Control Kit sets between 9 9 and 50 When the sensor is malfunctioning the air temperature is indicated as E1 NOTE 1 All technical installation and connection...

Страница 10: ...IRECT SMART BYPASS HIGH MID LOW SLEEP Filter Change Indicator About the Air Filter Lifespan 1 The need for change of the High Efficiency Combo Filter of every unit may differ depending on the kind of environment and the usage capacity Please replace the filter when necessary 2 Set the frequency of the air filter replacement according to the usage capacity and environment settings 3 The air flow an...

Страница 11: ...bo Filter 5 Use Vacumm Cleaner to Clean the Dust Dirt a Do not wash the filter with water or other substance as it may damage the filter and affect its functionability b Insert the High Efficiency Combo Filter back into the compartment after cleaning Take note of the correct direction of the filter before insertion 6 Switch on the Remote Control for Test Run When the Filter Change Indicator is lit...

Страница 12: ...MER SERVICE 1 Maintenance Service a Warranty Period 5 years b Within the first 18 months from the purchasing date the manufacturer is responsible for the service or replacement of any of the following faulty parts i Problems arising during the proper installation and usage guidelines as required in the user manual ii Problems arising from the repair maintenance or installation by the appointed tec...

Отзывы: