page 1

PREFACE

Thank you for purchasing the AireGard Fresh Air Supply Ventilator, FS-150! We hope that the product that you 

purchased from us will be delighting you always. Before you start using the product, we remind you to carefully 

read through this user manual to understand more about this product in order to avoid from any harm or risk of 

danger that could lead to unnessary damage or even personal injury.

PRODUCT SPECIFICATION

MODEL                                                                        SPEED     POWER   AIR FLOW   STATIC PRESSURE 

          WEIGHT

                                                                                                                   [ W ]           [m

3

/h ]                       [ Pa ]                                                  [ kg ]

RATED

VOLTAGE

[ V ]

FS-150

240 

        50

RATED

FREQUENCY

[ Hz ]

HIGH

MID

LOW

68

54

50

250

170

135

185

160

135

OPERATION MODES

WATER
PROOF

LEVEL

IPX2           9.5

NOTE :

1. The units of Air Flow, Voltage and other variances are measured under the condition of zero Static Pressure.

2. The measurement of Air Flow are obtained under the strictest monitoring within our research facility. The 

readings may varies within a difference range of    10%

DIMENSION & SPARE PARTS

NO.

NAME

QUANTITY

WIND DUCT   CIRCUIT    HANGER    METAL    HIGH EFFICIENCY    ACTIVATED CARBON   WIND   INSPECTION

   COMBO        PANEL 

           FILTER       COMBO FILTER 

           FILTER             TRAP        DOOR

Содержание FS-150

Страница 1: ...FRESH AIR SUPPLY VENTILATOR FS 150 USER MANUAL ...

Страница 2: ... Products Specification 1 Dimension Spare Parts 1 Packing List 2 IImportant Notice 2 Safety Precautions 3 Inspection Door Settings Check 4 Installation Guides 4 Filter Maintenance 8 Troubleshooting 10 Customer Service 10 ...

Страница 3: ...L SPEED POWER AIR FLOW STATIC PRESSURE WEIGHT W m3 h Pa kg RATED VOLTAGE V FS 150 240 50 RATED FREQUENCY Hz HIGH MID LOW 68 54 50 250 170 135 185 160 135 OPERATION MODES WATER PROOF LEVEL IPX2 9 5 NOTE 1 The units of Air Flow Voltage and other variances are measured under the condition of zero Static Pressure 2 The measurement of Air Flow are obtained under the strictest monitoring within our rese...

Страница 4: ...modes of the unit High Mid Low Stop with the help of the integrated temperature sensor to eliminate the likelihood of discomfort caused by the variances between indoor and outdoor temperature Hence it is absolutely normal that the operating modes of the unit may alter from time to time due to the change in temperature Under the normal circumstances of operating room temperature 10 40 the performan...

Страница 5: ...mpt on repairing the unit or any of its spare parts if there are any damages Ask for the help of the qualifies and trained professional for assistance WARNINGS PRECAUTIONS Do not place any foreign objects directly close to the air inlet or the air outlet of the unit Do not use open flames near the main unit as it may lead to possible high risk of fire hazard Do not place any foreign objects on the...

Страница 6: ...n weight of the unit The position of the 3 Hanging Screw Fastener are as indicated in the diagram 2 Installing the unit onto the Fastener Securely install the Screw Fastener layering loop and main screws optional by user use only M8 M10 types Main Screws Layering Loop Screw Fastener 3 Connect the Ducting Tightly secure the ducting to the connecting inlet or outlet and seal it with tapes The ductin...

Страница 7: ... Cloth Line 86 Box Control Kit Connect the Cloth line and the 86 Box Control Kit according to the Line Schematic Diagram on page 8 Copper Wire Connecting Earth Wire Fixed Cloth Line Unit in mm 86 Box Control Kit Wire Power Supply Wire Cap Earth Wire Live Wire Connecting Rod Screws 86 Box Control Kit Wire 86 Box Control Kit Wire B 86 BOX CONTROL KIT INSTALLATION 1 Remove the back cap a Use the Slot...

Страница 8: ...or and outdoor air quality is poor The PLUS mode can help to improve the overall air quality to enhance the cleanliness of the indoor air 1 Press the button to turn on the PLUS mode the wind default speed is set as HIGH To adjust the speed simply press the HIGH MID or LOW button 2 To turn off the PLUS mode press the button one more time to turn off Filter Change Temperature Wind Speed Modes PLUS D...

Страница 9: ...aner indoor air for all 1 Press the button to turn on the DIRECT mode the wind default speed is set as LOW 2 To turn off the SLEEP mode press the button one more time to turn off PRECAUTIONS The default air temperature indicated on the 86 Box Control Kit sets between 9 9 and 50 When the sensor is malfunctioning the air temperature is indicated as E1 NOTE 1 All technical installation and connection...

Страница 10: ...IRECT SMART BYPASS HIGH MID LOW SLEEP Filter Change Indicator About the Air Filter Lifespan 1 The need for change of the High Efficiency Combo Filter of every unit may differ depending on the kind of environment and the usage capacity Please replace the filter when necessary 2 Set the frequency of the air filter replacement according to the usage capacity and environment settings 3 The air flow an...

Страница 11: ...bo Filter 5 Use Vacumm Cleaner to Clean the Dust Dirt a Do not wash the filter with water or other substance as it may damage the filter and affect its functionability b Insert the High Efficiency Combo Filter back into the compartment after cleaning Take note of the correct direction of the filter before insertion 6 Switch on the Remote Control for Test Run When the Filter Change Indicator is lit...

Страница 12: ...MER SERVICE 1 Maintenance Service a Warranty Period 5 years b Within the first 18 months from the purchasing date the manufacturer is responsible for the service or replacement of any of the following faulty parts i Problems arising during the proper installation and usage guidelines as required in the user manual ii Problems arising from the repair maintenance or installation by the appointed tec...

Отзывы: