page 7
INSTALLATION GUIDES
Filter
Change
Temperature
Wind
Speed
Modes
PLUS DIRECT SMART BYPASS
HIGH MID LOW SLEEP
4. Using the “BYPASS” Mode
Applies for situation where there is a urgent need for a fast
change of indoor air, without filtering the air quality.
The “BYPASS” mode improve the overall air quality by reducing
heavy usage on the air filter, thus prolonging the lifespan of the
air filter.
1) Press the button to turn on the “BYPASS” mode, the wind
default speed is set as “HIGH” .
2) To turn off the “BYPASS” mode, press the button one
more time to turn off.
Filter
Change
Temperature
Wind
Speed
Modes
PLUS DIRECT SMART BYPASS
HIGH MID LOW SLEEP
3. Using the “SMART” Mode
Applies for situation where indoor air quality is poor and smart
sensor auto determine on the outdoor air quality.
The “SMART” mode can help to improve the overall air quality
by monitoring outdoor air quality to control amount of inward air
intelligently, while prolonging the Air Filter lifespan .
1) Press the button to turn on the “PLUS” mode, the wind
default speed is set as “MID” . The speed is not adjustable
during this mode function.
2) To turn off the “SMART” mode, press the button one more
time to turn off.
5. Setting the “SLEEP” Mode
Applies for situation where indoor air cleaning is necessary while
operating in a super quiet condition.
The “SLEEP” mode improve the overall air quality to provide
cleaner indoor air for all.
1) Press the button to turn on the “DIRECT” mode, the wind
default speed is set as “LOW” .
2) To turn off the “SLEEP” mode, press the button one more
time to turn off.
PRECAUTIONS
The default air temperature indicated on the 86 Box Control Kit sets between -9.9 and 50 .
When the sensor is malfunctioning, the air temperature is indicated as “E1”
NOTE :
1. All technical installation and connection works must be
carried out by professional trained technicians.
2. All wires laying and connection must fulfill the basic
requirements of distance allowance for Grade III
standards of maximum power current flow.
3. Use only power switch with permissible rated current
of 15A or more.
4. All wires must be safely insulated with cloth fabricated
cables, with cable diameter not lesser than 2.5mm
2
.
5. Strip the wires only within necessary lengths and
connect them accordingly. Over stripped wires may
cause short circuit or fire hazards.
6. Ensure that the outer cap is closed to avoid moisture
that will damage the unit. Avoid press too hard on the
wires when closing the cap.
86
Box
Control
Kit
N
L
240V ~ 50Hz
M
PM2.5
Main Valve
Control Motor
PM2.5
Sensor
M
Side Valve
Cross Motor
~
M
Fresh Air
Motor
Main
Control
Panel
Yellow / Green
Blue
Brown
Fresh Air
Temperature
Sensor
Main Current Switch
(not lower than
250V~15A)
Wire Connection
Schematic Drawing
Stop using the unit is any abnormal issues are detected. Contact the dealers or servicing agents
for inspection or technical support.
Filter
Change
Temperature
Wind
Speed
Modes
PLUS DIRECT SMART BYPASS
HIGH MID LOW SLEEP