Ibis 3 Owners Guide
Revision V1
Page
6
of
19
BEFORE INSTALLATION YOU MUST COMPLETE THE FOLLOWING STEPS
Checked that roof thickness is between 25 – 85mm. If roof is greater than 85mm
thick you will need an Ibis 3 Thick roof adapter (Part No 8102007) from
Aircommand. Note that this measurement must include any ‘H-Frames’ used.
Confirmed that the unit will be within ±5° of the horizontal plane.
The installation instruction sections (pages 7 - 10) have been read.
Roof strength has been assessed.
Position of the unit has been assessed for clearance on the roof and ceiling.
The installation hole will not cut through any wiring in the roof.
Mains power or battery driven inverter power supply has been isolated.
Selected the correct sealant for your application.
Safe work method for lifting unit onto the roof top has been assessed.
Installation must conform to local wiring regulations.
DO NOT attempt to modify or add components to the installation procedure.
This equipment must only be serviced by a licensed refrigeration mechanic.
If your installation varies from the method outlined please contact Aircommand for specialty advice.
WARNING
The unit weighs approximately 45kg, ensure a two person lift or use a mechanical hoist to avoid the risk of
injury.
Failure to properly install the unit or attempting to modify it in any way can be extremely hazardous and may result in
property damage and/or personal injury.
Aircommand will not be held responsible for issues arising from incorrect or improper installation methods.