I. PURPOSE 

The  Aircommand  Ibis  3  air conditioning  unit  was

 

designed  for  installation  on  the  roof  of  a  caravan  or  recreational  vehicle  to 

provide reverse cycle heating and cooling. The unit is intended for vehicles with roofs that are from 25 to 85mm thick. The unit 
must be installed so that it is within ±5° of the horizontal plane.  It is important that the unit is installed properly according to the 
recommended guidelines.  

II. ENSURING EFFECTIVE OPERATION 

The effectiveness of the air conditioner is dependent on several factors that contribute to the total heat load on the van. When 
an  Aircommand  unit  is  installed  in  a  van  or  motorhome  Aircommand  assumes  that  the  vehicle  manufacturer  or  owner  has 
properly assessed the potential heat load or sought expert advice and selected the appropriate capacity air conditioning unit. 

Roof hatches will significantly increase the heat load into the caravan. Where possible avoid installing roof hatches or only install 
hatches that can be effectively insulated. The increase in heat load far outweighs the gain from natural lighting. 

The following actions can be taken to reduce peak heat load and help the air-conditioner deliver the most comfort: 

 

Closing all doors, hatches, windows and blinds. Extend all annexes.  

 

Position the vehicle so that the annex will face the sun and protect the windows from direct solar radiation. 

 

Turning off unneeded appliances that might increase the heat load inside the van.  

 

Cook outside if possible. 

 

Park the caravan/RV in a shaded position. 

 

In  periods  of  extreme  high  temperature  it  is  recommended  to  start  the  air  conditioner  earlier  in  the  morning  to  greatly 
improve its ability to cope with the expected peak heat load.  

III. CONDENSATION 

In areas of high humidity, the humid air within the van will cause “sweating” or condensation in parts of the unit as the humid, 
warm air contacts the colder air discharged from the system. If this occurs please ensure the following: 

 

Close all doors, hatches, windows and blinds to limit the ingress of warm humid air. 

 

Avoid running the inside fan on LOW or AUTO in humid conditions. Running the fan on HIGH fan speed will result in higher 
airflow and reduce the tendency to have condensation form.  
 

Aircommand will not be held responsible for damage caused by condensation. 

 

IV. GENERATORS 

The Ibis 3 is designed to run using mains power, however many owners may want to use portable generators to run the unit 
when in remote locations. 

Any generator used should deliver high quality, pure sine wave, alternating current at 50Hz, and be 

able  to  handle  the  compressor  start  up  demand

.  Given  the  vast  range  in  quantity  and  quality  of  generators  on  the  market 

Aircommand  cannot  recommend  a  specific  model  or  brand.  Discuss  your  specific  requirements  with  the  generator  supplier 
directly and consider their recommendations.  
 

Aircommand  will  not  be  held  responsible  for damages due  to  the use  of  improper  generators and such use  may void your 
warranty. 

 

 

 

Содержание 8100001

Страница 1: ...________________________________________7 COMMISSIONING OF THE UNIT _________________________________________________________________11 MAINTENANCE_____________________________________________________...

Страница 2: ...olgenden Adresse registriert werden www aircommand com au registration html GARANTIE DE CLIMATISATION R FRIG R E Garantie pour l Australie Nous nous engageons par cette garantie faire rectifier gratui...

Страница 3: ...OR IBIS 3 AIRCONDITIONER Model Number 8100001 Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before installation The unit must be in...

Страница 4: ...from direct solar radiation Turning off unneeded appliances that might increase the heat load inside the van Cook outside if possible Park the caravan RV in a shaded position In periods of extreme hig...

Страница 5: ...tation of the This Way UP arrows on the carton If the unit has been upside down for any period of time then DO NOT install Contact Aircommand Australia for advice Plenum Carton 557 x 577 x 119mm Weigh...

Страница 6: ...n inverter power supply has been isolated Selected the correct sealant for your application Safe work method for lifting unit onto the roof top has been assessed Installation must conform to local wir...

Страница 7: ...nit and any obstructions Figure 1 Figure 1 Foot print of the roof top air conditioner over 360 x 360mm mounting hole The area at the back shown in cross hatch must be kept free of obstructions INTERNA...

Страница 8: ...SDS particularly those regarding PPE safe use disposal Apply the recommended sealant to the underside of the weather collar Figure 5 Figure 5 Recommended sealant path Flip the collar over and firmly p...

Страница 9: ...installed unit Insert the M8 Bolt assembly through the corner holes Figure 9 Engage the bolts into the unit Ensure that the hold down bars are aligned with their recess Tighten the 4 bolts evenly Tigh...

Страница 10: ...of the plenum will require additional fixtures Figure 13 IF REQUIRED Remove the cover caps Screw in countersunk wood screws provided Tighten until gap is gone Replace cover caps Figure 13 Extra screw...

Страница 11: ...nge fan speed Press MODE button until COOL is selected Figure 20 Figure 20 Select COOL mode Decrease the set point temperature below the room temperature by pressing the TEMPERATURE DOWN button Figure...

Страница 12: ...use higher concentrations of airborne particles and various other factors may result in the filters needing to be cleaned more often Replacement return air filters can be ordered directly from Aircom...

Страница 13: ...AUSTRALIA PTY LTD IBIS 3 MODEL NO 8100001 230V AC 50Hz REFRIGERANT 407C 870 G RATED CAPACITY COOLING 3100 W HEATING 2700 W POWER INPUT COOLING 1300 W HEATING 1210 W RATED CURRENT COOLING 5 8 A HEATIN...

Страница 14: ...s unit from standby to ON and vice versa 11 12 Temperature up down Increase or decrease the desired temperature set point for your comfort Also acts to increase decrease time during timer clock settin...

Страница 15: ...10 until the required speed is selected Figure 19 Press TEMPERATURE UP DOWN for your required set point temperature Figure 21 DRY MODE Turn unit ON Press MODE until DRY is displayed in the Mode Displ...

Страница 16: ...Ibis 3 Owners Guide Revision V1 Page 16 of 19 IBIS 3 COMPONENTS SPARE PARTS...

Страница 17: ...8101014 1 18 Hold down plate piping 8101015 1 19 Electrical box RHS 8101016 3 20 Electrical box lid RHS 8101017 1 21 Electrical box LHS 8101018 1 22 Electrical box lid LHS 8101019 1 23 Control card 5...

Страница 18: ...Ibis 3 Owners Guide Revision V1 Page 18 of 19 IBIS 3 WIRING DIAGRAM...

Страница 19: ...bris has not blocked the external air intake of the roof top unit Clear intake grille High outside air temperatures in cooling Take action to reduce your peak heat load extend awnings close blinds win...

Отзывы: