COMMISSIONING OF THE UNIT 

 

Turn the power on at the circuit breaker. 

 

Using the remote control (Item #6) press the 

ON/OFF button. 

Figure 17

. Each command from 

the remote control should be answered by a ‘beep’ 
from the receiver in the plenum.  

 

Figure 17 - Turn unit on 

 

 

Press the MODE button until FAN mode is 

selected. 

Figure 18

 

 

Figure 18 - Select FAN mode 

 

 

Press the FAN button to cycle through High 

– 

Medium 

– Low fan speeds. 

Figure 19

. Note air 

flow as the speeds change.  

 

Figure 19 - Change fan speed 

 

 

 

Press MODE button until COOL is selected. 

Figure 20

 

 

Figure 20 - Select COOL mode 

 

 

Decrease the set point temperature below the 
room temperature by pressing the 
TEMPERATURE DOWN button. 

Figure 21

. The 

compressor will start within three minutes. Run unit 
until you can feel cool air from plenum outlets. 

 

Figure 21 - Decrease SET POINT temperature 

 

Note:

 Regardless of the mode selected there will 

always be a delay before the compressor starts. This 
delay is to protect the compressor and cannot be over 
ridden. 

 

Set mode to HEAT, and increase the set point 

temperature above the room temperature. 

Figure 

22

. After the protection delay the compressor will 

start.  

 

Figure 22 - Change to HEAT mode and increase SET 

POINT 

Содержание 8100001

Страница 1: ...________________________________________7 COMMISSIONING OF THE UNIT _________________________________________________________________11 MAINTENANCE_____________________________________________________...

Страница 2: ...olgenden Adresse registriert werden www aircommand com au registration html GARANTIE DE CLIMATISATION R FRIG R E Garantie pour l Australie Nous nous engageons par cette garantie faire rectifier gratui...

Страница 3: ...OR IBIS 3 AIRCONDITIONER Model Number 8100001 Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before installation The unit must be in...

Страница 4: ...from direct solar radiation Turning off unneeded appliances that might increase the heat load inside the van Cook outside if possible Park the caravan RV in a shaded position In periods of extreme hig...

Страница 5: ...tation of the This Way UP arrows on the carton If the unit has been upside down for any period of time then DO NOT install Contact Aircommand Australia for advice Plenum Carton 557 x 577 x 119mm Weigh...

Страница 6: ...n inverter power supply has been isolated Selected the correct sealant for your application Safe work method for lifting unit onto the roof top has been assessed Installation must conform to local wir...

Страница 7: ...nit and any obstructions Figure 1 Figure 1 Foot print of the roof top air conditioner over 360 x 360mm mounting hole The area at the back shown in cross hatch must be kept free of obstructions INTERNA...

Страница 8: ...SDS particularly those regarding PPE safe use disposal Apply the recommended sealant to the underside of the weather collar Figure 5 Figure 5 Recommended sealant path Flip the collar over and firmly p...

Страница 9: ...installed unit Insert the M8 Bolt assembly through the corner holes Figure 9 Engage the bolts into the unit Ensure that the hold down bars are aligned with their recess Tighten the 4 bolts evenly Tigh...

Страница 10: ...of the plenum will require additional fixtures Figure 13 IF REQUIRED Remove the cover caps Screw in countersunk wood screws provided Tighten until gap is gone Replace cover caps Figure 13 Extra screw...

Страница 11: ...nge fan speed Press MODE button until COOL is selected Figure 20 Figure 20 Select COOL mode Decrease the set point temperature below the room temperature by pressing the TEMPERATURE DOWN button Figure...

Страница 12: ...use higher concentrations of airborne particles and various other factors may result in the filters needing to be cleaned more often Replacement return air filters can be ordered directly from Aircom...

Страница 13: ...AUSTRALIA PTY LTD IBIS 3 MODEL NO 8100001 230V AC 50Hz REFRIGERANT 407C 870 G RATED CAPACITY COOLING 3100 W HEATING 2700 W POWER INPUT COOLING 1300 W HEATING 1210 W RATED CURRENT COOLING 5 8 A HEATIN...

Страница 14: ...s unit from standby to ON and vice versa 11 12 Temperature up down Increase or decrease the desired temperature set point for your comfort Also acts to increase decrease time during timer clock settin...

Страница 15: ...10 until the required speed is selected Figure 19 Press TEMPERATURE UP DOWN for your required set point temperature Figure 21 DRY MODE Turn unit ON Press MODE until DRY is displayed in the Mode Displ...

Страница 16: ...Ibis 3 Owners Guide Revision V1 Page 16 of 19 IBIS 3 COMPONENTS SPARE PARTS...

Страница 17: ...8101014 1 18 Hold down plate piping 8101015 1 19 Electrical box RHS 8101016 3 20 Electrical box lid RHS 8101017 1 21 Electrical box LHS 8101018 1 22 Electrical box lid LHS 8101019 1 23 Control card 5...

Страница 18: ...Ibis 3 Owners Guide Revision V1 Page 18 of 19 IBIS 3 WIRING DIAGRAM...

Страница 19: ...bris has not blocked the external air intake of the roof top unit Clear intake grille High outside air temperatures in cooling Take action to reduce your peak heat load extend awnings close blinds win...

Отзывы: