Part Description 

 Part # 

QTY 

Screw M5x12 - White 

8101001 

13 

Canopy - Ibis 3 

8101020 

Speed clip - M5 

8101002 

13 

Base - Ibis 3 

8101030 

Evaporator housing 

8101005 

Evaporator fan deck 

8101006 

Compressor, horizontal 240V AC R407C 

0018260 

Fan mounting plate 

8101007 

Lead through clip - LHS 

8101003 

10 

Lead through clip - RHS 

8101004 

11 

Inside fan stud 

8101008 

12 

Accumulator holder 

8101009 

13 

Fan, centrifugal 310mm 

8101010 

14 

Outside coil, 3 row 

8101011 

15 

Hermetic piping assembly 

8101012 

16 

Inside coil, 2 row 

8101013 

17 

End plate, inside coil 

8101014 

18 

Hold down plate, piping 

8101015 

19 

Electrical box - RHS 

8101016 

20 

Electrical box lid - RHS 

8101017 

21 

Electrical box - LHS 

8101018 

22 

Electrical box lid - LHS 

8101019 

23 

Control card 

5601069 

24 

Capacitor - Compressor run 30uF / 450V 

4101072 

25 

Capacitor - Compressor start 64-77uF / 330V 

8101021 

26 

PTC  

8001042 

27 

Brace & Grille 

8102008 

28 

Spiral duct collar 

8102009 

29 

Spiral duct 

8102010 

30 

Weather collar 

5861001 

31 

Weather collar seal 

5861003 

32 

Bolt M8 x 120 

4001034 

33 

Ceiling bar 

1802063 

34 

Low profile plenum cover 

8102006 

35 

Cap, screw hole 

0018164 

36 

Air louver 

8102011 

37 

Return air filter 

8102044 

38 

IR Receiver board 

5601072 

39 

IR Receiver bezel 

8102011 

40 

IR receiver window 

8102012 

41 

Receiver push button 

8102013 

42 

Remote control with holder 

5601071 

 

 

Содержание 8100001

Страница 1: ...________________________________________7 COMMISSIONING OF THE UNIT _________________________________________________________________11 MAINTENANCE_____________________________________________________...

Страница 2: ...olgenden Adresse registriert werden www aircommand com au registration html GARANTIE DE CLIMATISATION R FRIG R E Garantie pour l Australie Nous nous engageons par cette garantie faire rectifier gratui...

Страница 3: ...OR IBIS 3 AIRCONDITIONER Model Number 8100001 Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before installation The unit must be in...

Страница 4: ...from direct solar radiation Turning off unneeded appliances that might increase the heat load inside the van Cook outside if possible Park the caravan RV in a shaded position In periods of extreme hig...

Страница 5: ...tation of the This Way UP arrows on the carton If the unit has been upside down for any period of time then DO NOT install Contact Aircommand Australia for advice Plenum Carton 557 x 577 x 119mm Weigh...

Страница 6: ...n inverter power supply has been isolated Selected the correct sealant for your application Safe work method for lifting unit onto the roof top has been assessed Installation must conform to local wir...

Страница 7: ...nit and any obstructions Figure 1 Figure 1 Foot print of the roof top air conditioner over 360 x 360mm mounting hole The area at the back shown in cross hatch must be kept free of obstructions INTERNA...

Страница 8: ...SDS particularly those regarding PPE safe use disposal Apply the recommended sealant to the underside of the weather collar Figure 5 Figure 5 Recommended sealant path Flip the collar over and firmly p...

Страница 9: ...installed unit Insert the M8 Bolt assembly through the corner holes Figure 9 Engage the bolts into the unit Ensure that the hold down bars are aligned with their recess Tighten the 4 bolts evenly Tigh...

Страница 10: ...of the plenum will require additional fixtures Figure 13 IF REQUIRED Remove the cover caps Screw in countersunk wood screws provided Tighten until gap is gone Replace cover caps Figure 13 Extra screw...

Страница 11: ...nge fan speed Press MODE button until COOL is selected Figure 20 Figure 20 Select COOL mode Decrease the set point temperature below the room temperature by pressing the TEMPERATURE DOWN button Figure...

Страница 12: ...use higher concentrations of airborne particles and various other factors may result in the filters needing to be cleaned more often Replacement return air filters can be ordered directly from Aircom...

Страница 13: ...AUSTRALIA PTY LTD IBIS 3 MODEL NO 8100001 230V AC 50Hz REFRIGERANT 407C 870 G RATED CAPACITY COOLING 3100 W HEATING 2700 W POWER INPUT COOLING 1300 W HEATING 1210 W RATED CURRENT COOLING 5 8 A HEATIN...

Страница 14: ...s unit from standby to ON and vice versa 11 12 Temperature up down Increase or decrease the desired temperature set point for your comfort Also acts to increase decrease time during timer clock settin...

Страница 15: ...10 until the required speed is selected Figure 19 Press TEMPERATURE UP DOWN for your required set point temperature Figure 21 DRY MODE Turn unit ON Press MODE until DRY is displayed in the Mode Displ...

Страница 16: ...Ibis 3 Owners Guide Revision V1 Page 16 of 19 IBIS 3 COMPONENTS SPARE PARTS...

Страница 17: ...8101014 1 18 Hold down plate piping 8101015 1 19 Electrical box RHS 8101016 3 20 Electrical box lid RHS 8101017 1 21 Electrical box LHS 8101018 1 22 Electrical box lid LHS 8101019 1 23 Control card 5...

Страница 18: ...Ibis 3 Owners Guide Revision V1 Page 18 of 19 IBIS 3 WIRING DIAGRAM...

Страница 19: ...bris has not blocked the external air intake of the roof top unit Clear intake grille High outside air temperatures in cooling Take action to reduce your peak heat load extend awnings close blinds win...

Отзывы: