INSTALLATION & OPERATING 

INSTRUCTIONS FOR 

IBIS 3

 

AIRCONDITIONER 

 

                   Model Number: 

8100001

 

 

Serial Number:                    . 

 

 Date Purchased:                  .  

 

 WARNING 

It is important that this installation manual is properly read and understood before 

installation. The unit must be installed by a qualified tradesperson. Failure to properly 

install the unit or attempting to modify it in any way can be extremely hazardous and 

may result in property damage and personal injury. 

 
 

Aircommand will not be held responsible for problems relating to incorrect 

or improper installation methods. 

Содержание 8100001

Страница 1: ...________________________________________7 COMMISSIONING OF THE UNIT _________________________________________________________________11 MAINTENANCE_____________________________________________________...

Страница 2: ...olgenden Adresse registriert werden www aircommand com au registration html GARANTIE DE CLIMATISATION R FRIG R E Garantie pour l Australie Nous nous engageons par cette garantie faire rectifier gratui...

Страница 3: ...OR IBIS 3 AIRCONDITIONER Model Number 8100001 Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before installation The unit must be in...

Страница 4: ...from direct solar radiation Turning off unneeded appliances that might increase the heat load inside the van Cook outside if possible Park the caravan RV in a shaded position In periods of extreme hig...

Страница 5: ...tation of the This Way UP arrows on the carton If the unit has been upside down for any period of time then DO NOT install Contact Aircommand Australia for advice Plenum Carton 557 x 577 x 119mm Weigh...

Страница 6: ...n inverter power supply has been isolated Selected the correct sealant for your application Safe work method for lifting unit onto the roof top has been assessed Installation must conform to local wir...

Страница 7: ...nit and any obstructions Figure 1 Figure 1 Foot print of the roof top air conditioner over 360 x 360mm mounting hole The area at the back shown in cross hatch must be kept free of obstructions INTERNA...

Страница 8: ...SDS particularly those regarding PPE safe use disposal Apply the recommended sealant to the underside of the weather collar Figure 5 Figure 5 Recommended sealant path Flip the collar over and firmly p...

Страница 9: ...installed unit Insert the M8 Bolt assembly through the corner holes Figure 9 Engage the bolts into the unit Ensure that the hold down bars are aligned with their recess Tighten the 4 bolts evenly Tigh...

Страница 10: ...of the plenum will require additional fixtures Figure 13 IF REQUIRED Remove the cover caps Screw in countersunk wood screws provided Tighten until gap is gone Replace cover caps Figure 13 Extra screw...

Страница 11: ...nge fan speed Press MODE button until COOL is selected Figure 20 Figure 20 Select COOL mode Decrease the set point temperature below the room temperature by pressing the TEMPERATURE DOWN button Figure...

Страница 12: ...use higher concentrations of airborne particles and various other factors may result in the filters needing to be cleaned more often Replacement return air filters can be ordered directly from Aircom...

Страница 13: ...AUSTRALIA PTY LTD IBIS 3 MODEL NO 8100001 230V AC 50Hz REFRIGERANT 407C 870 G RATED CAPACITY COOLING 3100 W HEATING 2700 W POWER INPUT COOLING 1300 W HEATING 1210 W RATED CURRENT COOLING 5 8 A HEATIN...

Страница 14: ...s unit from standby to ON and vice versa 11 12 Temperature up down Increase or decrease the desired temperature set point for your comfort Also acts to increase decrease time during timer clock settin...

Страница 15: ...10 until the required speed is selected Figure 19 Press TEMPERATURE UP DOWN for your required set point temperature Figure 21 DRY MODE Turn unit ON Press MODE until DRY is displayed in the Mode Displ...

Страница 16: ...Ibis 3 Owners Guide Revision V1 Page 16 of 19 IBIS 3 COMPONENTS SPARE PARTS...

Страница 17: ...8101014 1 18 Hold down plate piping 8101015 1 19 Electrical box RHS 8101016 3 20 Electrical box lid RHS 8101017 1 21 Electrical box LHS 8101018 1 22 Electrical box lid LHS 8101019 1 23 Control card 5...

Страница 18: ...Ibis 3 Owners Guide Revision V1 Page 18 of 19 IBIS 3 WIRING DIAGRAM...

Страница 19: ...bris has not blocked the external air intake of the roof top unit Clear intake grille High outside air temperatures in cooling Take action to reduce your peak heat load extend awnings close blinds win...