Содержание TDM880i

Страница 1: ...PS11129BENAC01 06 2017 TDM880i Instruction Manual...

Страница 2: ...rbus Defence and Space operates a policy of continuous development Airbus Defence and Space reserves the right to make changes and improvements to any of the products described in this document and th...

Страница 3: ...types making of cables 12 Installation procedure 13 Installing the TDM880i 13 Powering up considerations 14 Connecting the power supply 14 Cabling 14 Connecting the power supply 14 Special considerati...

Страница 4: ...ission TETRA Terminal Programming Tool TPT 24 AT interface 25 SDS interface 25 Alerting feature 26 TETRA Terminal Programming Tool TPT 26 AT interface 28 SDS interface 28 IGS feature 29 7 CONNECTOR IN...

Страница 5: ...very endeavour has been made to ensure the accuracy of this document some errors may exist If any errors are found by the reader Airbus Defence and Space Oy should be notified in writing Please state...

Страница 6: ...s with AIMD should keep the radio at least 20 cm 7 9 in away from the AIMD device If you have any reason to suspect that interference is taking place switch off your radio immediately and contact the...

Страница 7: ...will corrode electronic circuits Do not use or store the radio in dusty dirty areas Its moving parts can be damaged Do not store the radio in hot areas High temperatures can shorten the life of elect...

Страница 8: ...vides a set of digital I O lines that can be configured as inputs or outputs The outputs can be controlled by SDS messages the inputs can be used to trigger a status message or location sending to pre...

Страница 9: ...nded for indoor use in weather protected dry conditions only The power supply is CE approved and conforms to EU EMC requirements DC Power Cable CA 124 The DC power cable CA 124 has a matching connecto...

Страница 10: ...ithout permission Select the best suitable good quality antenna for the use case Airbus offers a selection of antennas for which you can find more information in the accessory catalogue Alternatively...

Страница 11: ...certain fault conditions emitted RF energy may affect to operation of these systems If necessary consult the vehicle dealer manufacturer to determine the immunity of vehicle electronic systems to RF...

Страница 12: ...ower supply to a battery or another DC supply so that the black wire is GND 0V the green wire is the IGS signal and the red wire is the VCC signal 10 6 16 0 V The maximum recommended length of the pow...

Страница 13: ...onal accessory CA 126 is available in Airbus Defence and Space to convert from a MMBX to a TNC female GPS RF cable The connector of the TDM880i board is a 50 impedance matching IPX connector female Hi...

Страница 14: ...connected to the radio module are fastened in a manner that does not cause bending twisting pushing pulling or vibrating in the connectors of the radio 11 Connect the power cable Set the IGS signal th...

Страница 15: ...n from the body of the vehicle NOT directly from the battery Lightning protection Protect the antennas in particular from lightning using lightning rods surge arrestors gas discharge tubes and or othe...

Страница 16: ...ct the DAU 9S cable to a COM port of a PC and then connect the DAU 9S with the CA 125 and radio module 3 Start the TETRA Terminal Programming Tool the version 2009 20 53 4 or later of TPT should be us...

Страница 17: ...gnition and powering the radio ON OFF accordingly see Section Ignition sense IGS functionality on page 21 Tracking and positioning The TDM880i can be configured to send its location information period...

Страница 18: ...il the correct time date are recovered After the successful retrieval of the correct time the Sleep mode functionality continues execution as configured Periodic reset Data terminals can be installed...

Страница 19: ...power and runs out of backup power the main clock of the device resets In this case the Time Recovery sequence is started during the next startup See Section Time recovery on page 19 When the device h...

Страница 20: ...03 and X102 connectors the levels of input and output signals are 5 V TTL excluding the FBUS and MBUS signal See Section CONNECTOR INTERFACES on page 31 In the CPU connector the inputs and outputs are...

Страница 21: ...y The power on off is controlled in the TDM880i through an IGS input signal The signal is provided through multiple connectors with multiple voltage level variants To power up the TDM880i raise any of...

Страница 22: ...message from a predefined SSI TETRA Terminal Programming Tool TPT The TPT can be used to configure the Sleep mode feature in two ways to configure the set of SSI from which the configuration SDS mess...

Страница 23: ...Table 5 Sleep mode parametrization SDS interface After a new configuration is retrieved a special acknowledgement message is sent to the configuration sender The format of the acknowledgement is as f...

Страница 24: ...d tracks the distance trigger expressed as meters Table 7 Location tracking parameters TETRA Terminal Programming Tool TPT The TPT can be used to configure the Location tracking feature in two ways to...

Страница 25: ...etrization AT interface SDS interface Parametrization of the Tracking functionality over an SDS message requires that the message format presented below is used Table 9 Tracking parametrization SDS in...

Страница 26: ...y to include alert statuses into LIP messaging Acknowledgement allowed from all numbers The alert specific parameters are IO line bound to alert Alert handling None SDS 1 or SDS 4 messaging when alert...

Страница 27: ...are 32 individual alerts which can be configured using the shown dialog to Send a status message on alert Send an SDS 4 on alert Configure the message contents and destination address In addition to t...

Страница 28: ...10 Allowed from all numbers 0011 Both enabled Sub block count 8 bits Number of sub blocks single block update supported currently Sub block ID 8 bits reserved Sub block size 8 bits reserved Message ty...

Страница 29: ...e 13 Acknowledgement message format IGS feature The IGS feature can be configured using the Mobile Parameterisation view shown in Figure 8 Explanation of parametrization The Power Off Timer gives the...

Страница 30: ...M 8 8 0 I S P E C I F I C P A R A M E T E R S PS11129BENAC01 TDM880i Instruction Manual 30 36 This document is the property of Airbus DS SLC and should not be copied or circulated without permission F...

Страница 31: ...ut cable CA 124 must be fuse protected VCC 5A IGS 1A Use the wire size AWG 12 or larger It is recommended to connect all the power cable pins according to Table 14 Table 14 Power supply connector X104...

Страница 32: ...supply 8 OVERTEMP out 2 78 V Over temperature indicator signal active high 9 MBUS in out 2 78 V MBUS serial line connect 560 pull down resistor to BSI line to switch MBUS from X901 to X103 requires r...

Страница 33: ...out 5 V Max current 200mA see Note 2 NC Do not connect 3 GPS_FIX out TTL GPS fix indicator signal active high 4 GND gnd 0 V Ground 5 IN_SERVICE out TTL In service indicator signal active high 6 POWER...

Страница 34: ...W typical average in addition to other power consumption when on Idle 960 mW typical average Sleep 864 mW typical average IGS in logic high state Shut down 3 6 mW typical average OPERATING TEMPERATURE...

Страница 35: ...y of Airbus DS SLC and should not be copied or circulated without permission T E C H N I C A L D A T A The mechanical dimensions of the TDM880i illustrated in Figure 10 and Figure 11 Figure 10 TDM880i...

Страница 36: ...obile Equipment GPS Global Positioning System GTS GPS Tracking Server IGS Ignition Sense I O Input output LED Light Emitting Diode LIP Location Information Protocol LNA Low Noise Amplifier MMBX Microm...

Страница 37: ...TRA TR APP 00093 02 03 EN PS11129BENAC01...