background image

 

© Copyright AirBench Ltd 2016 

 

Page 6 of 20 

FUSES 

Switched units: A fuse is provided on the switch front plate. 

Speed controlled units: An additional fuse is provided within the speed control panel. To check this fuse, 
remove the service panel; the speed control panel is mounted on the rear of the service panel. 

Ducted Units 

As standard, VertExes are configured to discharge upwards through the top of the unit, without ductwork. 
Ducting should not be retrofitted to the discharge from the unit without consultation with the manufacturer. 

When configured for exhaust to atmosphere via ductwork a discharge spigot will be visible. These units are 
designed to connect to ductwork of the same size as the discharge spigot (generally 250 or 300 mm diameter). 

Ducting should be installed by a professional and should not provide greater than 100 Pascals resistance. 
Flexible ducting should be avoided as it may cause excessive back-pressure on the fan, and lead to reduced 
airflow. 

Any other configuration is non-standard and should be discussed with the manufacturer. 

Assembly of Accessories 

These items apply only when they have been ordered with the VertEx. 

ENCLOSURE 

Enclosures are supplied flat packed for assembly at point of use. Each enclosure is supplied with installation 
drawings and assembly should follow the process laid out in these drawings. 

 

 

Содержание VertEx VA

Страница 1: ...Copyright AirBench Ltd 2016 Page 1 of 20 VertEx VA Operation and Maintenance This Edition 19 November 2019 AirBench Ltd 6b Commerce Way Colchester CO2 8HR www airbench com 44 0 1206 791191 AIRBENCH LT...

Страница 2: ...ACCESSORIES 6 Commissioning 7 GENERAL 7 IN HOUSE COMMISSIONING 7 Operation 8 PRIOR TO USE 8 GENERAL USE 8 Maintenance 10 FILTER CARE 10 SPARES 13 OTHER ROUTINE MAINTENANCE 15 Accessories 16 FILTER PR...

Страница 3: ...mmissioning certificate The filters are not self cleaning They must be maintained cleaned replaced as described within Do not mix incompatible materials e g steel and aluminium It is the users respons...

Страница 4: ...er specific maintenance information About VertEx VertEx is a self contained cross draught extraction system which utilises a fan and filter combination selected for your specific application to extrac...

Страница 5: ...mplete VertEx unit If using a forklift to position the top section on the base section always ensure operators are fully trained and that other users are outside the working zone of the forklift Once...

Страница 6: ...here via ductwork a discharge spigot will be visible These units are designed to connect to ductwork of the same size as the discharge spigot generally 250 or 300 mm diameter Ducting should be install...

Страница 7: ...Ensure all operators are aware of the filter maintenance routine required for this machine Once complete you should note this on the commissioning certificate and retain the certificate for future re...

Страница 8: ...full power Check the filter pressure gauge on the front of the unit If the needle on the gauge is showing in the upper red zone check the filter condition they may require cleaning or replacement This...

Страница 9: ...Copyright AirBench Ltd 2016 Page 9 of 20...

Страница 10: ...n the accompanying log sheet Take precautions and wear appropriate PPE when handing filters They may contain hazardous dusts i If using a vacuum cleaner to empty filters excessive cleaning will reduce...

Страница 11: ...Copyright AirBench Ltd 2016 Page 11 of 20 Doors can be heavy Wear appropriate hand and foot protection...

Страница 12: ...side or damaged MINIPLEAT FILTERS Mini pleat filters have fine paper pleats often around 5mm between pleats in a metal case This filter is not cleanable Replace the filter when it is stained on the c...

Страница 13: ...MEDIA PADS Media pads are green and white fibreglass pads held in a metal frame These filters are not cleanable When replacing the frame and clip which hold the pad can be reused Always replace with w...

Страница 14: ...Copyright AirBench Ltd 2016 Page 14 of 20...

Страница 15: ...tasks suggests additional issues contact the manufacturer for advice FILTER SEALS These sit behind the filters and prevent dust passing into the body of the bench and the exhaust airstream It is impor...

Страница 16: ...d operates at all times when the speed control or switch is powered Wheels Standard industrial rubber wheeled swivel castors are used The two front wheels are lockable Lock by pressing on the lever an...

Страница 17: ...bed maintenance routines are being completed and recorded within the system logbook Condition check of fan filters electrics Performance testing according to recommended face velocities Visual check t...

Страница 18: ...Copyright AirBench Ltd 2016 Page 18 of 20 TECHNICAL Arrangement...

Страница 19: ...0 700 600 175 0 48 2 4 VA121218 1270 1800 700 1200 270 0 74 3 9 VA180618 1870 1800 700 600 225 0 74 3 9 VA120624 1270 2400 700 600 190 0 48 2 4 VA121224 1270 2400 700 1200 285 0 74 3 9 VA180624 1870 2...

Страница 20: ...chinery Directive 2006 42 EC Low voltage Directive 2014 35 EU EN 60204 1 2018 Safety of machinery electrical equipment of machines general requirements EN 60335 2 80 Safety requirements for electric f...

Отзывы: