INSTALLATION 

 

General 

Unpack the unit and check for damage, if not already completed. 

The VertEx must be installed on a flat and level floor capable of carrying the weight of the unit. For nominal unit 
weights, see Specifications section at rear of manual. When determining an installation location, be aware that 
the air exhaust must discharge somewhere. Do not position the unit so all outlets are blocked. 

These models are designed to be moved into place using a forklift or pallet truck, taking care not to damage 
fittings on the base of the unit. 

Please note installation may be required when using certain accessories, external fansets, or ducting (see 
below). 

Modular System 

VertEx units are built as modular systems. For ease of shipping and installation, the top section may be shipped 
separately. The top section is fitted with forklift eyes to enable positioning; note that these eyes are not 
designed to lift the complete VertEx unit. 

If using a forklift to position the top section on the base section, always ensure operators are fully trained and 
that other users are outside the working zone of the forklift. Once loosely positioned, ensure mounting holes are 
aligned and seal tape is not disturbed; then bolt top section into position. 

Do not move the unit while the top section is not securely fastened. 

If in doubt, contact us for advice. 

Electrical 

WIRING 

VertEx is supplied as standard with an internal fan or fans. These are pre-wired to a switch or speed controller 
and fitted with a lead and plug for your convenience. Standard electrical supply is 240V/1Ph/50Hz. Certain 
models can be supplied with 110V/1Ph/50Hz internal fans if specified in advance; this is noted on the front left 
of each unit where applicable.  

BS7671 requires that the lead is appropriate for the working environment and you must satisfy yourself that the 
pre fitted lead is satisfactory. 

VertEx can be supplied configured for multi-unit installations. In this instance a single electrical panel with 
plugged connections will be provided. 

EARTH BONDING 

If in doubt consult a qualified electrician. 

Содержание VertEx VA

Страница 1: ...Copyright AirBench Ltd 2016 Page 1 of 20 VertEx VA Operation and Maintenance This Edition 19 November 2019 AirBench Ltd 6b Commerce Way Colchester CO2 8HR www airbench com 44 0 1206 791191 AIRBENCH LT...

Страница 2: ...ACCESSORIES 6 Commissioning 7 GENERAL 7 IN HOUSE COMMISSIONING 7 Operation 8 PRIOR TO USE 8 GENERAL USE 8 Maintenance 10 FILTER CARE 10 SPARES 13 OTHER ROUTINE MAINTENANCE 15 Accessories 16 FILTER PR...

Страница 3: ...mmissioning certificate The filters are not self cleaning They must be maintained cleaned replaced as described within Do not mix incompatible materials e g steel and aluminium It is the users respons...

Страница 4: ...er specific maintenance information About VertEx VertEx is a self contained cross draught extraction system which utilises a fan and filter combination selected for your specific application to extrac...

Страница 5: ...mplete VertEx unit If using a forklift to position the top section on the base section always ensure operators are fully trained and that other users are outside the working zone of the forklift Once...

Страница 6: ...here via ductwork a discharge spigot will be visible These units are designed to connect to ductwork of the same size as the discharge spigot generally 250 or 300 mm diameter Ducting should be install...

Страница 7: ...Ensure all operators are aware of the filter maintenance routine required for this machine Once complete you should note this on the commissioning certificate and retain the certificate for future re...

Страница 8: ...full power Check the filter pressure gauge on the front of the unit If the needle on the gauge is showing in the upper red zone check the filter condition they may require cleaning or replacement This...

Страница 9: ...Copyright AirBench Ltd 2016 Page 9 of 20...

Страница 10: ...n the accompanying log sheet Take precautions and wear appropriate PPE when handing filters They may contain hazardous dusts i If using a vacuum cleaner to empty filters excessive cleaning will reduce...

Страница 11: ...Copyright AirBench Ltd 2016 Page 11 of 20 Doors can be heavy Wear appropriate hand and foot protection...

Страница 12: ...side or damaged MINIPLEAT FILTERS Mini pleat filters have fine paper pleats often around 5mm between pleats in a metal case This filter is not cleanable Replace the filter when it is stained on the c...

Страница 13: ...MEDIA PADS Media pads are green and white fibreglass pads held in a metal frame These filters are not cleanable When replacing the frame and clip which hold the pad can be reused Always replace with w...

Страница 14: ...Copyright AirBench Ltd 2016 Page 14 of 20...

Страница 15: ...tasks suggests additional issues contact the manufacturer for advice FILTER SEALS These sit behind the filters and prevent dust passing into the body of the bench and the exhaust airstream It is impor...

Страница 16: ...d operates at all times when the speed control or switch is powered Wheels Standard industrial rubber wheeled swivel castors are used The two front wheels are lockable Lock by pressing on the lever an...

Страница 17: ...bed maintenance routines are being completed and recorded within the system logbook Condition check of fan filters electrics Performance testing according to recommended face velocities Visual check t...

Страница 18: ...Copyright AirBench Ltd 2016 Page 18 of 20 TECHNICAL Arrangement...

Страница 19: ...0 700 600 175 0 48 2 4 VA121218 1270 1800 700 1200 270 0 74 3 9 VA180618 1870 1800 700 600 225 0 74 3 9 VA120624 1270 2400 700 600 190 0 48 2 4 VA121224 1270 2400 700 1200 285 0 74 3 9 VA180624 1870 2...

Страница 20: ...chinery Directive 2006 42 EC Low voltage Directive 2014 35 EU EN 60204 1 2018 Safety of machinery electrical equipment of machines general requirements EN 60335 2 80 Safety requirements for electric f...

Отзывы: