11
Installing the Prox Sensor Cables
1. Locate the two 30-foot prox sensor extension cables in the
BinMaxx scale kit.
2. Label the ends of the cables that will be installed in the cab (LO
and HI).
3. Connect the appropriate prox cable ends to the cooresponding
prox sensor pigtail cables; one for LO and one for HI.
4. Route the cable into the cab (usually through the floor or firewall)
to be connected to the ComLink.
5. Connect the low prox cable to the interface jumper wire and then
the low prox port on the Comlink. Repeat with the high prox cable
and port. (see ComLink Wiring Harness drawing on page 14 for
identification).
6. Secure cables with zip ties as necessary.
Note: Please ensure that there is a minimum of 12 inches between the
wiring and the exhaust piping, or properly shield wiring to protect it from
heat.
Installing the Cab Electronics
Installing the ComLink
Do not install the ComLink in an open area of the cab. We recommend
installing the ComLink in a place where it can be accessed fairly easily
and will be safe from damage such as under an access panel or in the
doghouse.
Install to an Existing Wiring Harness
Secure the ComLink to any appropriate existing wire harness using
zip ties secured through the holes on each side of the ComLink.