18
Adjusting the LO PROX Sensor
To accommodate all sizes of bins, the LO PROX switch should be set to
turn on when the tallest bin is lifted a few inches off the ground. This is
typically about 50” from the ground.
1. Start the truck and wait for the scale to power up
2. Position the arm torque tube between 48” and 52” from the
ground, as close to 50” as possible
3. From the scale display, follow the steps below:
• Press ESC to reach the main menu
• Use ▲ or ▼ to select DIAGNOSTICS. Press ENTER
• Use ▲ or ▼ to select ECU. Press ENTER
• Use ▲ or ▼ to select SENSOR DATA. Press ENTER
• The A/D readings will display on the BinMaxx screen. Press
▼ until you see the data that reads PROX SWITCHES along
with values.
Desired Fork Heights for Proximity Sensors
Adjusting the Proximity Sensors
Содержание BinMaxx