![Air Torque AT045U Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/air-torque/at045u/at045u_mounting-and-operating-instructions_2875609023.webp)
EB AT-RP-4GU EN
8-1
Malfunctions
8 Malfunctions
The work described in this section is only to be performed by fully trained and qualified personnel.
8.1 Troubleshooting
Malfunction
Possible reasons
Reccomended action
Uneven rotation
Inadeguate supply
Check the supply system and make sure that the supply pressure is correct.
Missing lubricant
Disassemble the actuator, lubricate all the sliding parts and reassemble the
actuator.
Worn components
Disassemble the actuator, inspect and replace the worn/damaged compo-
nents.
Control system
Make sure the control system components are correctly assembled. Check
the control system documentation and contact the manufacturer.
Faulty valve
In case of actuator mounted over the valve, check the valve documentation
and contact the manufacturer.
Incomplete rotation
Incorrect stroke adjustment
Follow the indications in section 9.5.6 for correct stroke adjustment.
Foreign object left inside
Disassemble the actuator, inspect and remove any foreign object.
Incorrect assembly after maintenance
Disasseble and reassemble the actuator correctly.
Control system
Make sure the control system components are correctly assembled. Check
the control system documentation and contact the manufacturer.
Faulty valve
In case of actuator mounted over the valve, check the valve documentation
and contact the manufacturer.
Loss of power
Inadeguate supply pressure
Check the control system and make sure that the supply pressure is correct.
Supply pipe blocked, compressed or with
sealing problems
Check all the tubing and fittings, remove any foreign object/damaged
component.
Actuator seals leakage
Disassemble the actuator, inspect and replace any damaged seals.
blocked air exhaust hole
Remove plugs or foreign objects from the exhaust hole.
Faulty valve
In case of actuator mounted over the valve, check the valve documentation
and contact the manufacturer.
8.2 Emergency action
The plant operator is responsible for emergency action to be taken in the plant.
Note
Contact AIR TORQUE after-sales service (
JOGP
@airtorque.
EF
) for malfunctions not listed in the table.
Содержание AT045U
Страница 4: ...4 EB AT RP 4GU EN...
Страница 8: ...1 4 EB AT RP 4GU EN Safety instructions and measures...
Страница 10: ...2 2 EB AT RP 4GU EN Markings on the device...
Страница 18: ...5 4 EB AT RP 4GU EN Mounting and assembly...
Страница 20: ...6 2 EB AT RP 4GU EN Start up...
Страница 22: ...7 2 EB AT RP 4GU EN Operation...
Страница 24: ...8 2 EB AT RP 4GU EN Malfunctions...
Страница 37: ...10 2 EB AT RP 4GU EN Decomissioning...
Страница 41: ...12 2 EB AT RP 4GU EN Repairs...
Страница 43: ...13 2 EB AT RP 4GU EN Disposal...
Страница 45: ...14 2 EB AT RP 4GU EN...
Страница 50: ...EB AT RP 4GU EN 15 5 Annex...
Страница 51: ...15 6 EB AT RP 4GU EN...
Страница 52: ...EB AT RP 4GU EN 15 7...