11
AirLive SI-108 User Manual
254(0xFE) = -2°C
253(0xFD) = -3°C
252(0xFC) = -4°C
251(0xFB) = -5°C
Set Auto
Report
Condition
Trigger By
Room
Temperature
Change
30 (0x1E
0(0x00) = Disable AUTO report function
(Default)
1
(for saving battery life)
Auto report if room temperature is different
from last report.
1(0x01) = 1°F (0.5°C)
2(0x02) = 2°F (1°C)
3(0x03) = 3°F (1.5°C)
4(0x04) = 4°F (2°C)
5(0x05) = 5°F (2.5°C)
6(0x06) = 6°F (3°C)
7(0x07) = 7°F (3.5°C)
8(0x08) = 8°F (4°C)
Set Auto
Report
Condition By
Time Interval
34 (0x22)
Auto report by the following time interval.
1
1(0x01) = 1 Hr
2(0x02) = 2 Hrs
3(0x03) = 3 Hrs
4(0x04) = 4 Hrs
5(0x05) = 5 Hrs
6(0x06) = 6 Hrs
7(0x07) = 7 Hrs
8(0x08) = 8 Hrs (Default)
Numbering Format,
If the Gateway only support decimal numbering format, please change it to decimal value
accordingly.
1.5.3. Firmware update Over The Air (OTA)
The SI-108 is based on 500 series SoC and supports Firmware Update Command Class, it
can receives the updated firmware image sent by controller via the Z-wave RF media. It is a
helpful and convenient way to improve some function if needed.
Caution:
Do not running the OTA when the battery is running low.