    3. You can remove the entire electrical plate by disconnecting the motor connections and 
power line. Remove the three nuts in each upper right and left hand corner and one at the 
bottom in the middle.   
 
     4. This will allow you to receive the timer and replace them if necessary.     
 
Filter bag replacement for the 1200 Series Vacuums. 
     1. Removal 
      

A. Open upper service door and lower, clean out door located on   

                               the left side of the vacuum.   
 
                       

B. Firmly grasp top filter ring at the top going through the service  

                               door and lift toward the top of the unit.  The top filter ring is 
                               hooked into an eyebolt.  Slide the filter ring out of the eyebolt.   
 
 

C. The filter can now be pulled down and out through the bottom   

                                clean out door. 
 
 

D. To replace filter bags repeat procedure by reversing the above  

                                procedures. 
 
     2. Preparing new filter bags 
 

A. Remove A ring from top of the old bag by rotating the A ring  

                                counter clockwise until the ring is out of the bag. 
 
 

B. Remove bottom B ring from the bottom of the bag by rotating  

                               the ring out of the hold provided.   
 

      

 

C. To install rings in new bags by reversing the above  

                                procedures.   

 

Installation of the vacuum hose. 

 
 1. When the vacuum is shipped the vacuum hose is in the top of the box 
the unit came in. 
 
 2. The hose must be screwed counter clockwise into the vacuum inlet on 
the right side of the vacuum. 

 
Installation of the air hose on Models K552-, K52-, Series Vacuums. 

  
1. When the vacuum is shipped the air hose is located in the bottom of the 
vacuum. 
 
 2. Insert the hose through the hose guard on the left hand side of the 
vacuum.  Run the hose to the quick coupler on the compressor or solenoid 
valve on  the K52-9 models.  Push the quick coupler open and insert hose 
coupler on 
  the end of the hose into the quick coupler.  Holding the hose coupler into 
the quick coupler release the quick coupler.  The hose is now hooked up. 

Содержание K52

Страница 1: ...July 2016 1 701 Frontier Way Bensenville IL 60106 Phone 800 542 3336 Fax 630 350 8011 Website AIR KING COM SERVICE INSTALLATION FOR K52 K552 VACUUM UNIT AIR VACUUM UNITS UNITS 1200 SERIES...

Страница 2: ...5 4 General Specifications Page 6 5 Electrical Requirements Page 7 6 Mounting Instructions Page 8 7 Operating Instructions Page 9 8 Basic Maintenance Page 10 9 Replacement of Parts Page 11 12 10 Trou...

Страница 3: ...s may be present WARNING VACUUMS EQUIPPED WITH AIR COMPRESSORS K552 750 OR VACUUMS EQUIPPED WITH REMOTE AIR SOLENOIDS K52 9 1 Over inflation of tires may be dangerous Please consult your vehicle owner...

Страница 4: ...dels comes with a variety of optional features 1 Models can be set up for free operation or coin operation 2 Cut resistant hose Air Vacuum Air Vacuum Remote units only 3 Single hose reel assemblies Ai...

Страница 5: ...er parts of the unit are warranted for ninety days 5 Warranty covers parts and materials only warranty does not include labor or transportation costs of any kind 6 If unit or parts are returned to the...

Страница 6: ...r coated with a clear coat finish 5 Separate timer for each function vacuum or air 6 Money box secured with two medco plug locks on the 1200 series vacuum AIR KING MODEL K552 1 High quality H P Indust...

Страница 7: ...Breaker C 60 HZ Single Phase The use of the recommended wire size is required for proper operation of all models See wire size guide below If using aluminum wire increase gauge on size Building Vacuum...

Страница 8: ...ND MORE THAN 1 INCH ABOVE CONCRETE BECAUSE FLOOR OF VACUUM IS ONLY 2 INCHES ABOVE THE CONCRETE ELECTRICAL REQUIREMENTS K52 K52 9 120 VAC 20 AMP CIRCUIT BREAKER K552 750 120 VAC 40 AMP CIRCUIT BREAKER...

Страница 9: ...K552 or a K52 9 Air Vacuum and Air Vac remote follow these instructions A To operate the Vacuum side insert the correct amount of coin or coins into the money slot on the right hand side of the vacuu...

Страница 10: ...deco plug locks Turn locks clockwise half of turn until they click Remove keys unit is now secured 3 Cleaning Out Refuse Area 1200 Series Vacuums A Refuse area must be cleaned periodically Refuse area...

Страница 11: ...coin boxes bolts are located behind the coin boxes Refer to Basic Maintenance for lock removal 3 Run the power wire from the stub up through the hold provided at the bottom of the unit See wire size...

Страница 12: ...d screen and press adhesive side down onto where the old gasket and screen were 5 To install motors follow in reverse the above procedure Air Compressor Replacement for 1200 Series Vacuums 1 Turn Powe...

Страница 13: ...bags A Remove A ring from top of the old bag by rotating the A ring counter clockwise until the ring is out of the bag B Remove bottom B ring from the bottom of the bag by rotating the ring out of th...

Страница 14: ...If machine still does not start and ground fault kicks out then check fuse underneath the dome See parts identification section for location of fuse See page 8 for fuse replacement Replace fuse push r...

Страница 15: ...r clogged or broken hose Check for open door or damaged door gasket if gasket is damaged replace it Problem Vacuum has low suction 1 Check for plugged filter bags Clean out bags if plugged Check for h...

Страница 16: ...s 1 thru 7 Are Time setting switches Combine number of seconds to set the time Here Switch 3 20 Seconds Switch 6 160 Seconds are ON for a total run time 20 160 180 Seconds 3 minutes Coin setting Switc...

Страница 17: ...540 To adjust time and coins follow directions below Combine Open Switches to select Time Switches must lie flat towards the number in seconds and toward the open Combine Closed Switches to Select Si...

Отзывы: