STOPPING THE ENGINE
1. Turn off and unplug all electric loads. Never start or
stop the generator with electrical devices plugged in or
turned on.
FIG.27
2. Running with GASOLINE
:
Press the engine switch to
OFF
, turn the battery switch to
OFF
3.
Running with LPG
:
Turn off the LPG tank valve. Press
the engine switch to
OFF
, turn the battery switch to
OFF
, disconnect the quick connect from the generator,
shift the fuel selector switch to
GASOLINE.
FIG.28
4.
Make sure battery switch is always
OFF
after every
use. This will disconnect the battery from the circuit, and
prevent the battery from draining
. FIG.29
5. When turning off the generator after LPG operation,
make sure the LPG cylinder knob is in the fully closed
position.
FIG.29
FIG.27