background image

Doc

 

No.

 

FM5611

 

issue

 

C

 

Page

 

5

   

 

5.

 

 

MAXPAGE

 

KIT

  

 

The

 

Maxpage

 

kit

 

(Aidcall

 

Part

 

No.

 

E40119)

 

includes

 

the

 

Maxpage

 

Terminal

 

&

 

Antenna,

 

mini

 

keyboard,

 

12V/3A

 

boxed

 

power

 

supply,

 

12V/7Ah

 

rechargeable

 

battery,

 

mains

 

lead,

 

low

 

voltage

 

power

 

lead

 

and

 

a

 

serial

 

data

 

lead.

 

Note:

 

the

 

plug

top

 

PSU

 

also

 

in

 

the

 

kit

 

is

 

not

 

used.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TRANSMITTER

 

LED’s

 

 

The

 

RED

 

POWER

 

LED

 

should

 

be

 

permanently

 

illuminated

 

when

 

the

 

12V

 

PSU

 

is

 

connected.

 

The

 

GREEN

 

TRANSMITTING

 

LED

 

will

 

only

 

illuminate

 

when

 

a

 

signal

 

is

 

transmitted

 

to

 

the

 

Pagers.

  

 

POWER

 

SUPPLY

 

LED’s

 

 

The

 

GREEN

 

POWER

 

LED

 

should

 

be

 

permanently

 

illuminated

 

when

 

the

 

Mains

 

supply

 

is

 

healthy.

 

The

 

RED

 

FAULT

 

LED

 

will

 

illuminate

 

if

 

the

 

12V

 

output

 

or

 

battery

 

fuse

 

has

 

blown.

 

 

Whip

 

Antenna

 

(120mm

 

high)

 

with

 

BNC

 

Connector

 

Red

Power

 

LED

 

Desktop

 

Enclosure

 

226

 

x

 

160

 

x

 

70mm

 

(LxWxH)

 

Green

 

Transmitting

 

LED

 

Wall

 

Mounted

 

Enclosure

 

200

 

x

 

230

 

x

 

80mm

 

(HxWxD)

 

12V

 

7Ah

  

Rechargeable

 

Battery

 

2m

 

Mains

 

Lead

 

Green

Power

 

LED

Red

Fault

 

LED

Maxpage

 

Terminal

 

&

 

Antenna

12V/3A

 

Power

 

Supply

 

Hinged

 

Lid

 

(1

 

Screw

 

Fixing)

2

 

Line/16

 

Character

 

Backlit

 

LCD

 

Display

 

Backlit

 

Keyboard

 

Rear

 

Power

 

&

 

Data

 

Sockets

PS/2

 

Mini

 

Keyboard

 

1.5m

 

Power Lead

1.8m

 

Data

 

Lead

Содержание Touchsafe Pro E40119

Страница 1: ... of continual product improvement and reserves the right to modify the specification of its products If any variation to the details in this document are suspected please contact Aidcall s Technical Support Aidcall a business unit of Legrand Electric Ltd Cowley Road Blyth Riverside Business Park Blyth Northumberland NE24 5TF T 44 0 1670 357 431 www aidcall co uk ___________________________________...

Страница 2: ... both are compatible with Maxpage Terminals The Transmitter requires connection to the PSU and the Pager Port on a Touchsafe Pro Nursecall Panel Staff will then be alerted to a call no matter where they are via their portable Pagers The system can be setup so all calls are reported to all Pagers at all times or day night groups can be set so different Pagers can be alerted depending on the time of...

Страница 3: ... 6 of this manual for details of cable type recommended colour code and cable length restrictions This product should be located at least 2 metres away from any other electronic equipment Failure to provide this separation may result in reduced radio range Do not locate this product above a radiator or other heat source Do not expose to direct sunlight Do not submerge in water and do not use in da...

Страница 4: ... 6 EC has been put in place to ensure the safe disposal and recycling of batteries Return used batteries to your supplier or drop off at your local municipal waste recycling depot NTENTS 4 MAINTENANCE CARE For peace of mind and to ensure your system is maintained to the highest standard Aidcall recommend an annual maintenance contract This will provide vital assistance in times of need from a nati...

Страница 5: ...al is transmitted to the Pagers POWER SUPPLY LED s The GREEN POWER LED should be permanently illuminated when the Mains supply is healthy The RED FAULT LED will illuminate if the 12V output or battery fuse has blown Whip Antenna 120mm high with BNC Connector Red Power LED Desktop Enclosure 226 x 160 x 70mm LxWxH Green Transmitting LED Wall Mounted Enclosure 200 x 230 x 80mm HxWxD 12V 7Ah Rechargea...

Страница 6: ...anels connect to the one which is most centrally located on the site The battery backed power supply unit should be wall mounted within 1 5 metres of the Maxpage Terminal and within 2 metres of an un switched mains supply The mini keyboard simply plugs into the PS2 Keyboard socket on the rear of the Maxpage Terminal RADIO RANGE Construction materials such as foil backed plasterboard reinforced con...

Страница 7: ...he colour code in the table below Note the plug is fitted with a 240V AC 5A BS1362 fuse The PSU should only be opened during installation and service the lid must be screwed shut at all other times to prevent the risk of electric shock Never leave a live PSU unattended with the lid open LOW VOLTAGE LEAD Cut the socket female connector off one end of the DC extension lead provided in the kit Strip ...

Страница 8: ...inal CONNECTION DETAILS It is possible wire colours may change without notice it is good practice to check continuity of each wire colour to the relevant 9 Pin D Pin No with a digital meter before terminating Maximum 20m cable length between Panel and Maxpage Terminal Cut Socket off Lead Plug into Maxpage Terminal 1 8m Lead RS232 Interface Connection Pin No Colour Terminal Connect To 1 Red DCD 2 O...

Страница 9: ...Transmitter and the display will change to Adjust Baud and Ignore Busy settings as shown above and press to enter the display will change to Adjust Invert Data and Pocsag Tone settings as shown above and press to enter the display will change to Adjust Encoding setting as shown above then press DEL to go back to the menu shown below Press 2 for RS232 and the display will change to MAXPage 12 05AM ...

Страница 10: ... screen Press and hold both bracket keys together then press the 5 key the display will change to Press 2 to set the Time and the display will change to Press and to move across the fields and enter the time in 24 hour clock format i e 13 00 1PM Press SEND to set the time then press DEL to exit back through the menus to the standby screen If you want to send text messages direct to the Pagers from...

Страница 11: ...above Refer to the J25 Pager User Guide Aidcall Doc No FM5615 for more information Refer to the Scope Pager User Guide Aidcall Doc No FM5620 for more information S Select the Panel ID the Maxpage Terminal is being connected to from the Paging Panel pull down box Note this only needs to be set on the Master Panel ID 1 Press the Save button then Close to exit Enter the 3 digit Pager ID s in the boxe...

Страница 12: ...ion to ESPA Maxpage Select the Beep Codes you want the Pager to sound from the pull down boxes alongside each call type Note only 4 different beep patterns are available with the ESPA option see the Beep Code table below Set the Re Paging Delay from the pull down box if a pager call is not accepted when this period expires the call will be resent Press the Save button then Close to exit Select a Z...

Страница 13: ...voltage across the battery leads is between 13 6V DC and 14 2V DC 13 8V nominal If the battery shows any signs of damage swelling or leakage during an annual inspection it should be replaced immediately Only replace with the Manufacturers Approved battery type Yuasa NP7 12 12V 7Ah Sealed Lead Acid Rechargeable Battery Replacement batteries are available from Aidcall order Part No F00622 IMPORTANT ...

Страница 14: ...r Supply Unit Manufacturer Model Elmdene G13803N A Compliance Low Voltage 2006 95 EC EMC 2004 96 EC WEEE 2002 96 EC Type Switch Mode PSU with Electronic Overload Protection Input Voltage 90V to 264V AC 50 60Hz Output Voltage Current 13 6V to 14 2V DC 3A Nominal 13 8V Output Ripple 150mV peak to peak LED Indicators Green Mains Supply Healthy and Red Fault Fuse Blown Mains Fuse Protection T2 0A 20mm...