10.

 

 

SPECIFICATION

 

 

Maxpage

 

Terminal

 

 

Manufacturer

 

Commtech

 

Wireless

Approvals

 

FCC

 

Part

 

15,

 

FCC

 

68,

 

CE,

 

C

TICK

Transmission

 

Frequency

 

459.2750MHz

Transmission

 

Power

 

2

 

or

 

4

 

Watts

Transmission

 

Range

 

Up

 

to

 

1

 

Mile

 

Transmission

 

Protocol

 

POGSAG

 

512

 

bps

Antenna

 

¼

 

Wave

 

Whip

 

(120mm

 

high) with

 

Right

 

Angle

 

BNC

Keyboard

 

PS/2

 

88

 

Key

 

Mini

 

Qwerty

 

Keyboard

 

Serial

 

Interface

 

RS232

 

9600

 

baud

 

(ESPA

 

4.4.4

 

Protocol)

LED

 

Indicators

 

Red

 

=

 

Power

 

and

 

Green

 

=

 

Transmitting

Keypad

 

19

 

Key

 

Silicon

 

Keypad

 

with

 

green

 

LED

 

backlight

Display

 

16

 

Character

 

x

 

2

 

Line

 

LCD

 

with

 

yellow

 

LED

 

backlight

Recipient

 

Capacity

 

1000

 

Pagers

 

Max

Group

 

Capacity

 

20

 

Groups

 

each

 

with

 

up

 

to

 

10

 

members

Message

 

Length

 

200

 

Characters

 

Max

Real

 

Time

 

Clock

 

24

 

Hour

 

Format

Operating

 

Voltage

 

12

 

to

 

13.8VDC

 

Operational

 

Current

 

2A

 

max

 

Enclosure

 

Material

 

ABS

 

(Black)

Ingress

 

Protection

 

Rating

 

IP20

 

Dimensions

 

226mm

 

x

 

160mm

 

x

 

70mm

 

(LxWxH)

 

Weight

 

1kg

  

 

 

Power

 

Supply

 

Unit

 

 

Manufacturer/Model

 

Elmdene

 

G13803N

A

Compliance

 

Low

 

Voltage:

 

2006/95/EC,

 

EMC

 

2004/96/EC,

 

WEEE

 

2002/96/EC

 

Type

 

Switch

 

Mode

 

PSU

 

with

 

Electronic

 

Overload

 

Protection

 

Input

 

Voltage

 

90V

 

to

 

264V

 

AC

 

50/60Hz

Output

 

Voltage/Current

 

13.6V

 

to

 

14.2V

 

DC

 

@

 

3A

 

(Nominal

 

13.8V)

Output

 

Ripple

 

150mV

 

peak

 

to

 

peak

LED

 

Indicators

 

Green

 

=

 

Mains

 

Supply

 

Healthy

 

and

 

Red

 

=

 

Fault

 

(Fuse

 

Blown)

 

Mains

 

Fuse

 

Protection

 

T2.0A

 

20mm

 

HRC

Load

 

Fuse

 

Protection

 

F3.15A

 

20mm

 

Glass

Battery

 

Fuse

 

Protection

 

F1.0A

 

20mm

 

Glass

Enclosure

 

Material

 

Mild

 

Steel

 

with

 

Hinged

 

Lid

 

(Finish:

 

Stove

 

Enamelled

 

White)

 

Ingress

 

Protection

 

Rating

 

IP40

 

Dimensions

 

200mm

 

x

 

230mm

 

x

 

80mm

 

(HxWxD)

 

Weight

 

1.85kg

 

(excluding

 

battery)

Relative

 

Humidity

 

95%

 

RH

 

non

condensing

Operating

 

Temperature

 

Range

 

10

o

C

 

to

 

40

o

C

 

 

Standby

 

Battery

 

 

Manufacturer/Model

 

Yuasa

 

NP7

12

Type

 

12V

 

7Ah

 

Rechargeable

 

Lead

 

Acid

Dimensions

 

151mm

 

x

 

65mm

 

x

 

97.5mm

 

(LxWxH)

 

Weight

 

2.65kg

Operating

 

Temperature

 

Range

 

15

o

C

 

to

 

50

o

C

 

 

Mains

 

Lead

 

 

Approvals

 

BS

 

1363/A,

 

VDE

 

and

 

KEMA

Cable

  

2

 

metres

 

long

 

3

 

core

 

0.75

2

mm

 

(Colour:

 

Black)

Plug

 

BS

 

1363

 

moulded

 

non

rewireable

 

13A

 

UK

 

Plug

Fuse

 

Type/Rating

 

BS

 

1362

 

1”

 

240V

 

AC

 

5A

 

 

Содержание Touchsafe Pro E40119

Страница 1: ... of continual product improvement and reserves the right to modify the specification of its products If any variation to the details in this document are suspected please contact Aidcall s Technical Support Aidcall a business unit of Legrand Electric Ltd Cowley Road Blyth Riverside Business Park Blyth Northumberland NE24 5TF T 44 0 1670 357 431 www aidcall co uk ___________________________________...

Страница 2: ... both are compatible with Maxpage Terminals The Transmitter requires connection to the PSU and the Pager Port on a Touchsafe Pro Nursecall Panel Staff will then be alerted to a call no matter where they are via their portable Pagers The system can be setup so all calls are reported to all Pagers at all times or day night groups can be set so different Pagers can be alerted depending on the time of...

Страница 3: ... 6 of this manual for details of cable type recommended colour code and cable length restrictions This product should be located at least 2 metres away from any other electronic equipment Failure to provide this separation may result in reduced radio range Do not locate this product above a radiator or other heat source Do not expose to direct sunlight Do not submerge in water and do not use in da...

Страница 4: ... 6 EC has been put in place to ensure the safe disposal and recycling of batteries Return used batteries to your supplier or drop off at your local municipal waste recycling depot NTENTS 4 MAINTENANCE CARE For peace of mind and to ensure your system is maintained to the highest standard Aidcall recommend an annual maintenance contract This will provide vital assistance in times of need from a nati...

Страница 5: ...al is transmitted to the Pagers POWER SUPPLY LED s The GREEN POWER LED should be permanently illuminated when the Mains supply is healthy The RED FAULT LED will illuminate if the 12V output or battery fuse has blown Whip Antenna 120mm high with BNC Connector Red Power LED Desktop Enclosure 226 x 160 x 70mm LxWxH Green Transmitting LED Wall Mounted Enclosure 200 x 230 x 80mm HxWxD 12V 7Ah Rechargea...

Страница 6: ...anels connect to the one which is most centrally located on the site The battery backed power supply unit should be wall mounted within 1 5 metres of the Maxpage Terminal and within 2 metres of an un switched mains supply The mini keyboard simply plugs into the PS2 Keyboard socket on the rear of the Maxpage Terminal RADIO RANGE Construction materials such as foil backed plasterboard reinforced con...

Страница 7: ...he colour code in the table below Note the plug is fitted with a 240V AC 5A BS1362 fuse The PSU should only be opened during installation and service the lid must be screwed shut at all other times to prevent the risk of electric shock Never leave a live PSU unattended with the lid open LOW VOLTAGE LEAD Cut the socket female connector off one end of the DC extension lead provided in the kit Strip ...

Страница 8: ...inal CONNECTION DETAILS It is possible wire colours may change without notice it is good practice to check continuity of each wire colour to the relevant 9 Pin D Pin No with a digital meter before terminating Maximum 20m cable length between Panel and Maxpage Terminal Cut Socket off Lead Plug into Maxpage Terminal 1 8m Lead RS232 Interface Connection Pin No Colour Terminal Connect To 1 Red DCD 2 O...

Страница 9: ...Transmitter and the display will change to Adjust Baud and Ignore Busy settings as shown above and press to enter the display will change to Adjust Invert Data and Pocsag Tone settings as shown above and press to enter the display will change to Adjust Encoding setting as shown above then press DEL to go back to the menu shown below Press 2 for RS232 and the display will change to MAXPage 12 05AM ...

Страница 10: ... screen Press and hold both bracket keys together then press the 5 key the display will change to Press 2 to set the Time and the display will change to Press and to move across the fields and enter the time in 24 hour clock format i e 13 00 1PM Press SEND to set the time then press DEL to exit back through the menus to the standby screen If you want to send text messages direct to the Pagers from...

Страница 11: ...above Refer to the J25 Pager User Guide Aidcall Doc No FM5615 for more information Refer to the Scope Pager User Guide Aidcall Doc No FM5620 for more information S Select the Panel ID the Maxpage Terminal is being connected to from the Paging Panel pull down box Note this only needs to be set on the Master Panel ID 1 Press the Save button then Close to exit Enter the 3 digit Pager ID s in the boxe...

Страница 12: ...ion to ESPA Maxpage Select the Beep Codes you want the Pager to sound from the pull down boxes alongside each call type Note only 4 different beep patterns are available with the ESPA option see the Beep Code table below Set the Re Paging Delay from the pull down box if a pager call is not accepted when this period expires the call will be resent Press the Save button then Close to exit Select a Z...

Страница 13: ...voltage across the battery leads is between 13 6V DC and 14 2V DC 13 8V nominal If the battery shows any signs of damage swelling or leakage during an annual inspection it should be replaced immediately Only replace with the Manufacturers Approved battery type Yuasa NP7 12 12V 7Ah Sealed Lead Acid Rechargeable Battery Replacement batteries are available from Aidcall order Part No F00622 IMPORTANT ...

Страница 14: ...r Supply Unit Manufacturer Model Elmdene G13803N A Compliance Low Voltage 2006 95 EC EMC 2004 96 EC WEEE 2002 96 EC Type Switch Mode PSU with Electronic Overload Protection Input Voltage 90V to 264V AC 50 60Hz Output Voltage Current 13 6V to 14 2V DC 3A Nominal 13 8V Output Ripple 150mV peak to peak LED Indicators Green Mains Supply Healthy and Red Fault Fuse Blown Mains Fuse Protection T2 0A 20mm...