background image

Doc

 

No.

 

FM5611

 

issue

 

C

 

Page

 

3

   

 

2.

 

 

IMPORTANT

 

SAFETY

 

INSTRUCTIONS

 

 
 

 

 

 

Read

 

and

 

understand

 

these

 

instructions

 

before

 

use.

 

Keep

 

these

 

instructions

 

for

 

future

 

reference.

 

 

 

 

Isolate

 

the

 

mains

 

supply

 

before

 

removing

 

the

 

PSU

 

cover.

 

 

Do

 

not

 

disassemble

 

the

 

Maxpage

 

Terminal/PSU

 

or

 

attempt

 

to

 

repair

 

it

 

yourself.

  

 

No

 

user

 

serviceable

 

parts

 

inside.

 

Refer

 

all

 

servicing

 

to

 

qualified

 

service

 

personnel.

 

 

 

The

 

PSU

 

should

 

only

 

be

 

connected

 

to

 

a

 

220

240VAC

 

50/60Hz

 

mains

 

supply.

 

If

 

you

 

are

 

unsure

 

of

 

the

 

type

 

of

 

power

 

supply

 

consult

 

your

 

local

 

power

 

company.

 

 

Danger

 

of

 

explosion

 

if

 

the

 

PSU

 

rechargeable

 

battery

 

is

 

incorrectly

 

replaced.

 

Use

 

only

 

manufacturer

 

approved

 

battery

 

as

 

identified

 

in

 

section

 

9

 

of

 

this

 

manual.

  

 

Only

 

use

 

manufacturer

 

approved

 

cable

 

during

 

installation.

 

See

 

section

 

6

 

of

 

this

 

manual

 

for

 

details

 

of

 

cable

 

type,

 

recommended

 

colour

 

code

 

and

 

cable

 

length

 

restrictions.

 

 

 

 

This

 

product

 

should

 

be

 

located

 

at

 

least

 

2

 

metres

 

away

 

from

 

any

 

other

 

electronic

 

equipment.

  

Failure

 

to

 

provide

 

this

 

separation

 

may

 

result

 

in

 

reduced

 

radio

 

range.

 

 

Do

 

not

 

locate

 

this

 

product

 

above

 

a

 

radiator

 

or

 

other

 

heat

 

source.

  

 

Do

 

not

 

expose

 

to

 

direct

 

sunlight.

  

Do

 

not

 

submerge

 

in

 

water

 

and

 

do

 

not

 

use

 

in

 

damp

 

or

 

humid

 

conditions.

 

 

Do

 

not

 

expose

 

this

 

product

 

to

 

dripping

 

or

 

splashing

 

water.

  

Liquids

 

can

 

cause

 

a

 

failure

 

and/or

 

a

 

fire

 

hazard.

 

 

Clean

 

with

 

a

 

damp

 

cloth

 

and

 

a

 

non

abrasive

 

cleaning

 

product.

 

Polish

 

with

 

a

 

dry

 

duster.

 

DO

 

NOT

 

use

 

a

 

wet

 

cloth.

  

 

 

 

Avoid

 

using

 

harsh,

 

abrasive

 

or

 

corrosive

 

cleaning

 

agents

 

or

 

detergents

 

(e.g.

 

scouring

 

powders,

 

bleaches,

 

polishes,

 

etc.)

 

when

 

cleaning

 

this

 

product.

 

 

 

 

At

 

the

 

end

 

of

 

its

 

life

 

this

 

product

 

should

 

be

 

disposed

 

of

 

and

 

recycled

 

in

 

accordance

 

with

 

the

 

environmental

 

regulations.

 

See

 

the

 

Regulatory

 

Information

 

in

 

section

 

3

 

below.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание Touchsafe Pro E40119

Страница 1: ... of continual product improvement and reserves the right to modify the specification of its products If any variation to the details in this document are suspected please contact Aidcall s Technical Support Aidcall a business unit of Legrand Electric Ltd Cowley Road Blyth Riverside Business Park Blyth Northumberland NE24 5TF T 44 0 1670 357 431 www aidcall co uk ___________________________________...

Страница 2: ... both are compatible with Maxpage Terminals The Transmitter requires connection to the PSU and the Pager Port on a Touchsafe Pro Nursecall Panel Staff will then be alerted to a call no matter where they are via their portable Pagers The system can be setup so all calls are reported to all Pagers at all times or day night groups can be set so different Pagers can be alerted depending on the time of...

Страница 3: ... 6 of this manual for details of cable type recommended colour code and cable length restrictions This product should be located at least 2 metres away from any other electronic equipment Failure to provide this separation may result in reduced radio range Do not locate this product above a radiator or other heat source Do not expose to direct sunlight Do not submerge in water and do not use in da...

Страница 4: ... 6 EC has been put in place to ensure the safe disposal and recycling of batteries Return used batteries to your supplier or drop off at your local municipal waste recycling depot NTENTS 4 MAINTENANCE CARE For peace of mind and to ensure your system is maintained to the highest standard Aidcall recommend an annual maintenance contract This will provide vital assistance in times of need from a nati...

Страница 5: ...al is transmitted to the Pagers POWER SUPPLY LED s The GREEN POWER LED should be permanently illuminated when the Mains supply is healthy The RED FAULT LED will illuminate if the 12V output or battery fuse has blown Whip Antenna 120mm high with BNC Connector Red Power LED Desktop Enclosure 226 x 160 x 70mm LxWxH Green Transmitting LED Wall Mounted Enclosure 200 x 230 x 80mm HxWxD 12V 7Ah Rechargea...

Страница 6: ...anels connect to the one which is most centrally located on the site The battery backed power supply unit should be wall mounted within 1 5 metres of the Maxpage Terminal and within 2 metres of an un switched mains supply The mini keyboard simply plugs into the PS2 Keyboard socket on the rear of the Maxpage Terminal RADIO RANGE Construction materials such as foil backed plasterboard reinforced con...

Страница 7: ...he colour code in the table below Note the plug is fitted with a 240V AC 5A BS1362 fuse The PSU should only be opened during installation and service the lid must be screwed shut at all other times to prevent the risk of electric shock Never leave a live PSU unattended with the lid open LOW VOLTAGE LEAD Cut the socket female connector off one end of the DC extension lead provided in the kit Strip ...

Страница 8: ...inal CONNECTION DETAILS It is possible wire colours may change without notice it is good practice to check continuity of each wire colour to the relevant 9 Pin D Pin No with a digital meter before terminating Maximum 20m cable length between Panel and Maxpage Terminal Cut Socket off Lead Plug into Maxpage Terminal 1 8m Lead RS232 Interface Connection Pin No Colour Terminal Connect To 1 Red DCD 2 O...

Страница 9: ...Transmitter and the display will change to Adjust Baud and Ignore Busy settings as shown above and press to enter the display will change to Adjust Invert Data and Pocsag Tone settings as shown above and press to enter the display will change to Adjust Encoding setting as shown above then press DEL to go back to the menu shown below Press 2 for RS232 and the display will change to MAXPage 12 05AM ...

Страница 10: ... screen Press and hold both bracket keys together then press the 5 key the display will change to Press 2 to set the Time and the display will change to Press and to move across the fields and enter the time in 24 hour clock format i e 13 00 1PM Press SEND to set the time then press DEL to exit back through the menus to the standby screen If you want to send text messages direct to the Pagers from...

Страница 11: ...above Refer to the J25 Pager User Guide Aidcall Doc No FM5615 for more information Refer to the Scope Pager User Guide Aidcall Doc No FM5620 for more information S Select the Panel ID the Maxpage Terminal is being connected to from the Paging Panel pull down box Note this only needs to be set on the Master Panel ID 1 Press the Save button then Close to exit Enter the 3 digit Pager ID s in the boxe...

Страница 12: ...ion to ESPA Maxpage Select the Beep Codes you want the Pager to sound from the pull down boxes alongside each call type Note only 4 different beep patterns are available with the ESPA option see the Beep Code table below Set the Re Paging Delay from the pull down box if a pager call is not accepted when this period expires the call will be resent Press the Save button then Close to exit Select a Z...

Страница 13: ...voltage across the battery leads is between 13 6V DC and 14 2V DC 13 8V nominal If the battery shows any signs of damage swelling or leakage during an annual inspection it should be replaced immediately Only replace with the Manufacturers Approved battery type Yuasa NP7 12 12V 7Ah Sealed Lead Acid Rechargeable Battery Replacement batteries are available from Aidcall order Part No F00622 IMPORTANT ...

Страница 14: ...r Supply Unit Manufacturer Model Elmdene G13803N A Compliance Low Voltage 2006 95 EC EMC 2004 96 EC WEEE 2002 96 EC Type Switch Mode PSU with Electronic Overload Protection Input Voltage 90V to 264V AC 50 60Hz Output Voltage Current 13 6V to 14 2V DC 3A Nominal 13 8V Output Ripple 150mV peak to peak LED Indicators Green Mains Supply Healthy and Red Fault Fuse Blown Mains Fuse Protection T2 0A 20mm...

Отзывы: