13
However, if the number of CO Alarms is limited, the following points should be considered when
deciding where best to fit the alarm(s).
- If there is an appliance in a room where people sleep, place a CO Alarm in this room
- Locate a CO Alarm in a room containing a flueless or open-flued appliance
- Locate a CO Alarm in a room where the occupant(s) spend most of their time (e.g. living room)
- In a bedsit, the CO Alarm should be placed as far away from the cooking appliance as possible, but
near to where the occupant sleeps
- If the appliance is in a room not normally used (such as a boiler room) the CO Alarm should be
placed just outside the room so that the alarm will be heard more easily.
2.3 Which Alarm In what room?
Location
Ei3028
Heat and CO
Alarm
Ei3018
CO
Alarm
Kitchens with Fuel Burning appliance
ᅛ
Garages with Fuel Burning appliance
ᅛ
Boiler houses
ᅛ
Areas with high levels of fumes, smoke or dust and
risk of CO
ᅛ
Any other rooms with Fuel Burning appliance
ᅛ
Any other rooms with risk of CO poisoning
ᅛ
Содержание Ei3018
Страница 4: ...4 1 Introduction Installer Guide...
Страница 10: ...10 2 Installation...
Страница 24: ...24 3 What is Carbon Monoxide User Guide...
Страница 32: ...32 4 Testing...
Страница 37: ...37 5 What to do in case of FIRE...
Страница 39: ...39 6 What to do in case your Alarm detects Carbon Monoxide...
Страница 41: ...41 7 Troubleshooting and Indicator summary tables...
Страница 51: ...51 8 Important Safeguards...
Страница 54: ...54 9 Service and Guarantee...
Страница 57: ...57 KM86596 KM83678 EN50291 1 2010 A1 2012 BS5446 2 2003...
Страница 58: ...58...
Страница 59: ...59...