INSTRUCTIONS FOR USE
AGP 1000 – 2000 PRO
Rev.02/2019
32
7.5
Mixing nozzle
Figure 7.3
To ensure better mixing, the
machine is fitted with one or two
mixing nozzles, integrated into the
bottom part of the reservoir. The
mixing nozzle is controlled by
means of the diverter valve mounted
on the pressure regulator. The
mixing nozzle is active when the
diverter valve is open. During the
preparation of the spraying mixture
and when driving to the field, it is
recommended to keep the mixing
nozzle in operation.
7.6
Suction filter
The suction filter is mounted between the reservoir and the pump. Its function is filtering the
insecticide before it reaches the regulator. The size of the filter is 50 MESH.
7.6.1
Cleaning filter insert
Firstly, unscrew the yellow lever (3) on the filter cover (2) by turning it counter clockwise and
pulling it out. The valve mounted inside the filter will close the flow of the liquid from the main
reservoir. Unscrew the nut (5) from the filter cover and remove the cover and the filter insert (4).
Clean the filter insert and mount all parts back together in the reverse order.
When mounting the parts back together, make sure that the metal pin of the locking valve, which
is located at the extracted part (with a yellow lever) will be properly inserted, otherwise the filter
will not function properly.
Figure 7.4
WARNING: Use protective gloves when cleaning the filter!
Clean the filter insert before each filling of the reservoir!