INSTRUCTIONS FOR USE
AGP 1000 – 2000 PRO
Rev.02/2019
65
Required power for pump
operation (50 bar)
P (kW)
10.7
Required power for fan
operation (i = 1 : 5; P (pump) =
0 (bar))
P (kW)
22.6
Total required power for
operation (50 bar)
P (kW)
33.3
15.1
Characterization
The spraying appliances are characterised as follows:
For example: AGP 1000 PRO; PR8ECF/2EMV; APS 121; 1070/14/2
•
AGP ....... abbreviation for spraying appliances
•
1000 ....... nominal capacity of the reservoir
•
PRO ........ version, type
•
PR8F/2EMV ..... Regulator type (PR8) with a high-pressure cleaning filter (F) and two (2)
diverter valves (EMV)
•
APS 121 .... Pump type
•
1070/14/2 …. blower type, height (1070), number of nozzles (14), number of sections (2)
All other technical data for individual components (pumps, flow regulators etc.) can be found in
individual chapters. Technical data for nozzles with the tables and examples of consumption
calculations are given in the following pages.
15.2
Sprayer disposal
Once the spraying appliance cannot be used anymore, you will have to clean it completely, take it
apart and sort the individual components of the sprayer by material. The components must be
handed over to an organisation which deals with waste materials. The reservoir and other plastic