7.7
Nozzle for cleaning interior of main reservoir
Figure 7.5
Nozzle is mounted in the interior of main
reservoir and is intended for washing of
reservoir's interior after finished spraying. It
is connected to one of the supply valves on
pressure regulator, which, when open,
provides required water for cleaning.
7.8
Strainer and packaging cleaner
This accessory ensures easier handling of spraying agents. The strainer contains a special nozzle,
which directs the liquid from the nozzle towards the bottom part of the strainer to flush out the
spraying agent (powder) added through the strainer. It also enables packaging cleaning. The
cleaner is attached to the one-way diverter valve of the pressure regulator or directional control
valve by means of a hose connection between the valve and the mixing nozzle.
When the diverter valve for packaging and strainer cleaning is opened, it is necessary to adjust the
pressure (5-10 bar). This activates the strainer rinsing function, which is useful for rinsing powder-
based spraying agents (1). If liquid spraying agents are used, the protective film under the
packaging lid can be penetrated with the pointy top of the rinsing nozzle. (2). When the entire
content of the packaging (bottle) is emptied, push the neck of the bottle or plastic container over
the nozzle and to the limiter (3). This activates the nozzle, which thoroughly washes the inside of
the packaging. When the packaging is removed, the flow is closed.
Figure 7.6
WARNING: The nozzle shape shown in the figure is symbolic and may not
reflect the actual state of equipment on the mist blower!