Technical specifications 

 

Packaging dimensions: 220x160x50 mm (LxWxH) 

 

Package weight: 450 g 

 

Device dimensions: 73 x 52 x 33 mm (WxHxD) 

 

Weight: 230 g 

 

Dust and waterproof plastic housing 

 

3 internal control buttons for configuration 

 

Six-digit display with 11 mm digit height 

 

Icons for displaying additional information 

 

Powered by 2 x AAA batteries 

 

Battery life approx. 3 years 

6

 

Configuration 

6.1

 

Selection of the operating mode  

The AGRETO AgriCounter Load has 2 operating modes. In the first mode, only 

the amount of loads are counted, in the second mode additionally the working 

hours are counted. 
First, decide which operating mode is suitable to your application, set the 

required settings if necessary, and then mount the counter on your machine! 

Overview of the modes: 

Operating mode 

Output 

Activation by 

3 A (default) 

Loads 

Location / sequenz 

3 B 

Loads 
Operation hours 

Location / sequenz 
Vibration / movements 

Содержание AgriCounter Load

Страница 1: ...AGRETO electronics GmbH User Manual AGRETO AgriCounter Load 12 7 2019...

Страница 2: ...oad 7 6 5 Setting the parameters 8 6 6 Zeroing the counter 12 7 Assembly 13 7 1 Positioning of the meter 13 7 2 Fixing the mounting plate 13 7 3 Fastening the counter 14 7 4 Attaching the seal 14 8 Wo...

Страница 3: ...arts Manual 3 Intended use The AGRETO AgriCounter Load is designed for the counting of loads on slurry tanks with level indicators and transport vehicles with moving parts The activation takes place b...

Страница 4: ...rom tip over fall and inattention while working with the measuring instrument during getting on and off the tractor 4 3 Personal protective equipment WARNING For individuals who work with the device o...

Страница 5: ...by 2 x AAA batteries Battery life approx 3 years 6 Configuration 6 1 Selection of the operating mode The AGRETO AgriCounter Load has 2 operating modes In the first mode only the amount of loads are co...

Страница 6: ...rom the menu Minus Back to the previous step Decrease a parameter by 1 Plus Continue to the next step Increase a parameter by 1 6 3 Setting the operating mode On delivery the operating mode 3A is pres...

Страница 7: ...nk is approximately half full the angle set in parameter A1 is exceeded Now the time t1 set in the parameter starts to run This status is indicated by the up arrow The filling process continues The co...

Страница 8: ...name of the parameter is displayed for two seconds then the set value appears Use the or keys to change the value of the parameter Use the M key to change to the next parameter the set value is saved...

Страница 9: ...ition This angle distinguishes between full and empty 0 default pointer is horizontal 90 maximum adjustable angle pointer is vertically upwards 90 minimum adjustable angle pointer is vertically downwa...

Страница 10: ...oad will be counted if the pointer fluctuates 1 lowest settable time in seconds 60 default 1000 maximum settable time in seconds Parameter t2 Time below the center position This parameter sets how lon...

Страница 11: ...unter waits after a first move to actually start the totalization permanently If there is another movement within the set time which is strong enough the time from the first movement is added up and t...

Страница 12: ...hours and minutes hhhh mm 00 99 display in hours with 2 decimal places hhhh hh By default the display is in hours and minutes and the colon is used as the separator If necessary you can change the di...

Страница 13: ...which is once per deployed load in a certain angular position for example on an actuating linkage or a discharge hatch or cover 7 2 Fixing the mounting plate On delivery the meter is mounted on the m...

Страница 14: ...then tighten every screw again so that the housing is evenly pressed against the mounting plate 7 4 Attaching the seal Thread the seal wire through the holes in the two screws Thread both ends of the...

Страница 15: ...not provided The symbol X indicates that the displayed number is the sum of the loads 8 2 Reading the hours The AgriCounter Vibration permanently displays the sum of the counted hours an operation is...

Страница 16: ...device up transport position The wavy line means that the counter is currently detecting movement or vibration and is in counting mode The x means that the displaying of the loads is active The h mean...

Страница 17: ...vice in the specified direction Mount the counter again on the mounting plate Seal the device again with a new seal wire and a new seal 10 2 Loads are not counted completely It is likely that the sequ...

Страница 18: ...rs even with minor movements To hold longer periods of rest during operation set the parameter hOLd upwards 10 5 Too many operating hours are counted Perhaps the machine is exposed to light movements...

Страница 19: ...e warranty period begins with the first accounting to an end customer and ends 5 years from this date of invoice Prerequisite for warranty service are the presentation of the original invoice and comp...

Страница 20: ...technical changes or design changes All information in this manual are supplied without liability despite careful preparation A liability by the author is excluded Copyright 2019 AGRETO electronics G...

Отзывы: