7
Assembly
Only start with the assembly once you have clarified whether a change in the
configuration is necessary for your application. Please read the chapter
"Configuration" before.
7.1
Positioning of the meter
The most common application for the
AgriCounter Load is the installation
directly on the level indicator of a
slurry tanker. It is not a problem if the
level indicator is narrower than the
housing of the AgriCounter.
The assembly is also possible on any moving part, which is once per deployed
load in a certain angular position, for example, on an actuating linkage or a
discharge hatch or cover.
7.2
Fixing the mounting plate
On delivery, the meter is mounted on the
mounting plate. Disassemble the meter from
the mounting plate.
Hold the mounting plate in the desired
position to the desired mounting position.
Use the mounting plate as a template and
mark the 2 holes with a pin.
Hit one notch each with a grain.
Drill the 2 holes with a 4.2 mm diameter drill.
Deburr the 2 holes.
Use a M5 screw tap to cut a thread in each hole.
Use the 2 M5x25 allen screws and the 2 aluminum washers and screw the
base plate to the machine. Note that the sealing surface of the base plate
is pointing towards the meter.