Parameter t1 – Time above the center position
This parameter sets how long the pointer must be in total above the center
position to reach the "full" state.
This time prevents a double count of a load when the pointer fluctuates. It
should not exceed half the filling time, the shortest journey to the unloading
point and half the emptying time.
If the time is set too high, the load will not be counted. If the time is set too low
there is a risk that an additional load will be counted if the pointer fluctuates.
1 = lowest settable time in seconds
60 = default
1000 = maximum settable time in seconds
Parameter t2 – Time below the center position
This parameter sets how long the pointer must be in total below the center
position to reach the "empty" state.
This time prevents a double count of a load when the pointer fluctuates. It
should not exceed half the emptying time, the shortest journey to the loading
point and half the filling time.
If the time is set too high, the load will not be counted. If the time is set too low
there is a risk that an additional load will be counted if the pointer fluctuates.
1 = lowest settable time in seconds
60 = default
1000 = maximum settable time in seconds