background image

1

N o k e v a l

    Manual

No  250803

Model 2800-2061

Scalable counter for

pulse sensors

Содержание 2800-2061

Страница 1: ...1 Nokeval Manual No 250803 Model 2800 2061 Scalable counter for pulse sensors...

Страница 2: ...2 Manufacturer Nokeval Oy Yritt j katu 12 37100 NOKIA FINLAND Tel 358 0 3 342 4800 Fax 358 0 3 342 2066 http www nokeval com...

Страница 3: ...ries where by changing the input output cards the display can be modified to other input values such as temperature serial or frequency input Two power suppliy possibilities one for 85 240 VAC and the...

Страница 4: ...485 Serial output only for measurement reading Baud rate and address RS485 selectable Relays You can set alarm value by button inside the case Relay contacts max 230 VAC 0 5 A Alternatively semi condu...

Страница 5: ...supply 12 V max 50 mA Power supply 24 V Default max 150 mA Connector Jumper setting for contact input Max input frequence 40 Hz 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 8 9 Slot A Slot B Slot C Relay 1 REL...

Страница 6: ...rs 0 9 and decimal Setting of alarm value You can set alarm value by keys number by number Setting starts from largest number from left to right You may go to next number by X key Exit by key Alarm se...

Страница 7: ...selection normally closed NO External switch contact selection normally open Dec Number of desimals How many desimals are shown in display Int 0 15 Intensity of display Change the display intensity fr...

Страница 8: ...ng program In case you can not choose serial card slot has automatically recognized card plug and play Terminalconnections By serial signal RS485 last unit must be terminated by 110 ohm resistor you c...

Страница 9: ...e actual com mand including the ETX In the example the ASCII codes have been presented in hexadecimal e g One wants the measurement result from the display unit address 1 To the channel an inquiry is...

Страница 10: ...with current input thermocouple strain gage etc Additional slots Additionalcardsprovide output 4 20 mA alarms serial interface BCD output etc Meter data sheet dictates possible combina tions grey con...

Страница 11: ...Modular field display series 2800 6543 21 5 6 digit red LED display Power supply 85 240VACor 12 32 VDC 24 VAC Optioncards Alarm cards 2 relay card 4 alarm types change over contacts 3 relay card clos...

Страница 12: ...12...

Страница 13: ...13...

Страница 14: ...14 Manufacturer Nokeval Oy Yritt j katu12 37100 NOKIA Finland Tel 358 0 3 342 4800 Fax 358 0 3 342 2066 email mail nokeval com http www nokeval com...

Отзывы: