6 Language Dictionary
78
Series N6700 User’s Guide
SCPI Command
Description
[SOURce:] (continued)
VOLTage
[:LEVel]
[:IMMediate][:AMPLitude] <NRf+>, (@chanlist)
Sets the output voltage
:TRIGgered [:AMPLitude] <NRf+>, (@chanlist)
Sets the triggered output voltage
:MODE FIXed | STEP | LIST, (@chanlist)
Sets the voltage trigger mode
:PROTection
[:LEVel] <NRf+>, (@chanlist)
Sets the over-voltage protection level
:RANGe <NRf+>, (@chanlist)
Sets the output voltage range (Agilent N6761A/62A)
:SLEW <NRf+> | INFinity, (@chanlist)
Sets the output voltage slew rate
STATus
:OPERation
[:EVENt]? (@chanlist)
Returns the value of the operation event register
:CONDition? (@chanlist)
Returns the value of the operation condition register
:ENABle <NRf>, (@chanlist)
Enables specific bits in the Event register
:NTRansition <NRf>, (@chanlist)
Sets the Negative transition filter
:PTRansition <NRf>, (@chanlist)
Sets the Positive transition filter
:PRESet
Presets all enable and transition registers to power-on
:QUEStionable
[:EVENt]? (@chanlist)
Returns the value of the questionable event register
:CONDition? (@chanlist)
Returns the value of the questionable condition register
:ENABle <NRf>, (@chanlist)
Enables specific bits in the Event register
:NTRansition <NRf>, (@chanlist)
Sets the Negative transition filter
:PTRansition <NRf>, (@chanlist)
Sets the Positive transition filter
SYSTem
:CHANnel
[:COUNt]?
Returns the number of output channels in a mainframe
:MODel? (@chanlist)
Returns the model number of the selected channel
:OPTion? (@chanlist)
Returns the option installed in the selected channel
:SERial? (@chanlist)
Returns the serial number of the selected channel
:COMMunicate
:RLSTate LOCal | REMote | RWLock
Specifies the Remote/Local state of the instrument
:TCPip:CONTrol?
Returns the control connection port number
:ERRor?
Returns the error number and error string
:GROup
:CATalog?
Returns the groups that have been defined
:DEFine (@chanlist)
Group multiple channels together to create a single output
:DELete (channel)
Removes the specified channel from a group
:ALL
Ungroups all channels
:PASSword:FPANel:RESet
Resets the front panel lock password to zero
:REBoot
Returns the unit to its power-on state
:VERSion?
Returns the SCPI version number
TRIGger
:ACQuire
(Acquire commands only on Agilent N6761A/62A and Option 054)
[:IMMediate] (@chanlist)
Triggers the measurement immediately
:SOURce BUS | PIN<pin> | TRAN<chan>, (@chanlist)
Sets the measurement trigger source
:TRANsient
[:IMMediate] (@chanlist)
Triggers the output immediately
:SOURce BUS | PIN<pin> | TRAN<chan>, (@chanlist)
Sets the output trigger source