background image

 

5

Installation Note

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

38-pin probe and adapter cable dimensions

Содержание E5346A

Страница 1: ...to a small area of a target system The Agilent Technologies E5346A probe has RCR isolation networks in the cable end that connects to the 38 pin AMP MICTOR Matched Impedance ConnecTOR connector The A...

Страница 2: ...to select the part number of the correct shroud for your board thickness The kits listed consist of 5 MICTOR connectors and 5 support shrouds 4 Connect either the 38 pin probe or 38 pin adapter cable...

Страница 3: ...7D 16710A 16711A 16712A 16715A 16716A 16717A 16718A 16719A 16750A 16751A or 16752A The following equivalent probe load diagram includes the logic analyzer and 38 pin MICTOR connector Equivalent probe...

Страница 4: ...gilent publication number 5968 4632E Probing Solutions for Agilent Technologies Logic Analysis Systems for help on the terminations when using the Agilent Technologies E5351A 38 Pin Adapter Cable Use...

Страница 5: ...5 Installation Note Agilent Technologies E5346A 38 Pin Probe and E5351A 38 Pin Adapter Cable 38 pin probe and adapter cable dimensions...

Страница 6: ...ter Cable Notice the holes for mounting the support shrouds in the following illustration One of the holes is off center to allow 0 40 in 1 02 mm centers when using multiple connectors Board pad detai...

Страница 7: ...7 Installation Note Agilent Technologies E5346A 38 Pin Probe and E5351A 38 Pin Adapter Cable Support shroud dimensions...

Страница 8: ...not connect these pins They are SCL and SDA which are used by the logic analyzer with an emulator or analysis probe preprocessor to program or read target information Pins 6 8 10 38 These pins are od...

Страница 9: ...5 3 D15 even 7 7 D14 even 9 9 D13 even 11 11 D12 even 13 13 D11 even 15 15 D10 even 17 17 D9 even 19 19 D8 even 21 21 D7 even 23 23 D6 even 25 25 D5 even 27 27 D4 even 29 29 D3 even 31 31 D2 even 33...

Страница 10: ...and DC return for analysis probes 5 VDC 1 1 39 1 39 GROUND 3 2 40 2 40 Do not connect the following pins They are used by the logic analyzer with an emulator or analysis probe to program or read targ...

Страница 11: ...terminal must be connected to the earth termi nal of the power source Whenever it is likely that the ground protection is impaired you must make the instrument inoperative and secure it against any u...

Страница 12: ...ocument Warranty The material contained in this document is provided as is and is subject to being changed without notice in future editions Further to the maximum extent permitted by applica ble law...

Отзывы: