background image

8

Remove the Outer and Inner Signal Generator Covers

Removing the Outer Cover

Refer to 

Figure 1

.

1. Disconnect the power cord.

2. Using a T-20 driver, remove the two strap handles (1) by loosening the screws.

3. Using a T-15 driver, remove the center screws (3) on the four rear-panel feet (2).

4. Remove the four bottom feet (5) and (6) from the cover by lifting the tab and sliding the foot.

5. Slide the outer cover (4) off the frame.

Removing the Inner Top Cover

Refer to 

Figure 1

.

1. Using a T-10 driver, remove the ten screws (8) from the inner-top cover (7).

2. Remove the inner-top cover.

Содержание E4438CK-601

Страница 1: ...ted in USA October 2006 Supersedes April 2006 Agilent Technologies ESG Vector Signal Generator Upgrade Kits for Options 601 and 602 Digital Bus Baseband Generator with 8 and 64 Msample Memory respecti...

Страница 2: ...o this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Agilent Technologies shall not be liable for errors contained herein or for...

Страница 3: ...erator operation 2 Install new firmware Firmware version C 04 54 must be installed before completing Step 6 3 Initialize the signal generator memory 4 Remove the outer and inner signal generator cover...

Страница 4: ...0 80545 7 1 W10 AUX I O Cable 8121 0679 8 1 W12 BNC Cable Baseband Generator Reference IN 8121 0643 9 2 Screw SMM 3 0x8 for Digital Bus Cable Retainer 0515 0372 10 5 Hex Nut 15 21 32 AUX I O 2950 0035...

Страница 5: ...Long nose pliers Safety Considerations WARNING Before you disassemble the signal generator turn the power switch off and unplug the power cord Failure to unplug the signal generator can result in pers...

Страница 6: ...mmary of the test results is displayed after completion of the self test Refer to the service guide to troubleshoot any failures detected by the test NOTE Some circuits may require up to 50 minutes to...

Страница 7: ...obtained in step 2 5 Click Initialize Option 601 and 602 NOTE To undo the previous steps press Restore Factory Setup If you do not have access to a LAN 1 Use a PC or UNIX workstation with GPIB or RS...

Страница 8: ...oosening the screws 3 Using a T 15 driver remove the center screws 3 on the four rear panel feet 2 4 Remove the four bottom feet 5 and 6 from the cover by lifting the tab and sliding the foot 5 Slide...

Страница 9: ...9 Figure 1 Outer and Inner Cover Removal...

Страница 10: ...EVENT 1 EVENT 2 PATT TRIG IN and BURST GATE IN connectors 1 4 Using a small Phillips screw driver remove the two screws from the DIG I Q I O connector 2 5 Using the 5 mm nut driver remove the shoulder...

Страница 11: ...rator Board from the A23 Motherboard 4 Remove the A7 Digital Bus Baseband Generator board 5 Insert the new A7 Digital Bus Baseband Generator board into the front and rear card cage guides in Slot 1 6...

Страница 12: ...12 Figure 3 Connecting W92...

Страница 13: ...25P1 on the A25 Rear Panel Board is towards the assembly labeled 1 in Figure 5 Failure to do so could result in damage to the A25 Rear Panel Board connector Figure 4 Cable Connector 2 Insert the narro...

Страница 14: ...14 Figure 5 Digital Bus Cable Retainer 2 3 1...

Страница 15: ...front panel display The Host ID is needed to obtain the license key for Option 601 or 602 3 Go to the GSDC website http www agilent com find software license with your Entitlement certificate The cer...

Страница 16: ...nd generator will function properly in most applications without recalibrating the signal generator If EVM performance is critical to your application run the performance tests listed below Refer to t...

Отзывы: