Using the Breadboard
Reading Data From Input Registers
To read data from the TR0 - TR15 Data Input lines, read the data from the
I/O register at 14
h
in A24 memory space. Figure 2-3 illustrates the timing
required for reading data from this register on the Agilent E2259A
Breadboard. You only have access to the DBEN* and LAT* control lines;
the other control line waveforms are provided for reference information
only.
Figure 2-3. Timing of Reading Data from Registers
MSYSCLK
DS0*
DS1*
CS*
DTACK*
MA(7:0)
MD(15:0)
RPn
(16MHz)
62.5 ns
62.5 ns
62.5 ns
190 ns
< 40 ns
62.5 ns
DBEN*
LAT*