32 Using the Relay Matrix Switches
Chapter 2
Relay Matrix Switch
Query Commands
All query commands end with a "?". All data is sent to the output buffer
where you can retrieve it into your computer. The following are valid query
commands:
Power-on and Reset
Conditions
When power is first applied to the Relay Matrix Switch modules or *RST
(reset) is executed, all relays are open. This table lists the parameters
and default values for the switchbox functions described in this chapter.
Commands in brackets ( [ ] ) are implied and are not sent with the command.
Query
Description
ARM:COUN?
Number of Scanning Cycles
CLOS?
Channel Closed
INIT:CONT?
Scanning State
OPEN?
Channel Open
OUTP:ECLTn?
ECL Trigger Output State
OUTP:EXT?
External Trigger Output State
OUTP:TTLTn?
TTL Trigger Output State
STAT:OPER:ENAB?
Status Operation Enable
STAT:OPER[:EVEN]?
Status Operation Event
SYST:CDES? <number>
Module Description
SYST:CTYP? <number>
Module Type
SYST:ERR?
System Error
TRIG:SOUR?
Trigger Source
Parameter
Default
Description
ARM:COUNt
1
Number of scanning cycles is 1
TRIGger:SOURce
IMM
Will advance scanning cycles
automatically
INITiate:CONTinuous
OFF
Number of scanning cycles set by
ARM:COUNt
OUTPut[:EXTernal][:STATe]
OFF
Trigger output from EXTernal,
TTLTrg, or ECLTrg sources is
disabled
Содержание E1468A
Страница 2: ......
Страница 6: ...6 Notes...
Страница 10: ...10 Notes...
Страница 14: ...14 Getting Started Chapter 1 Figure 1 3 E1468A E1469A Connector Pin Out...
Страница 30: ...30 Getting Started Chapter 1 Notes...
Страница 68: ...68 Relay Matrix Switch Specifications Appendix A Notes...
Страница 78: ...78 Relay Matrix Switch Error Messages Appendix C Notes...
Страница 83: ...E1468 90005 Manual Part Number E1468 90005 Printed in U S A E1200...
Страница 84: ......